涉及电工死亡的冠状病毒调查:一个系统思维的视角
David Waugh1, Sharon Newnam2, David Rodwell2
1School of Psychology and Counselling, Queensland University of Technology, Australia.
International journal of occupational safety and ergonomics : JOSE
|December 20, 2025
概括
电工死亡事故是复杂的系统问题,而不仅仅是个别错误. 在验尸官报告中应用的系统思维揭示了各个系统层面的多种贡献因素,支持风险管理框架.
科学领域:
- 职业健康和安全问题 职业健康和安全问题
- 系统工程 系统工程
- 事故调查事故调查
背景情况:
- 电气工作在全球范围内构成重大风险,尽管采取了安全措施,但死亡事故仍然存在.
- 传统的调查往往侧重于工人错误,忽视系统性问题.
研究的目的:
- 用系统思维方法分析澳大利亚电工死亡事故的因果因素.
- 评估拉斯穆森风险管理框架 (RMF) 对电气事故的适用性.
主要方法:
- 因果因素是从11个澳大利亚验尸官关于电死事故的报告中提取出来的.
- 使用AcciMap可视化因素相互关系和系统级别.
- 这些因素与RMF的七个关键预测进行了测试.
主要成果:
- 电气事故涉及到许多超出前线工作人员范围的因果因素.
- 分析支持拉斯穆森的RMF的所有七个关键预测.
- 电气行业被确定为一个复杂的社会技术系统.
结论:
- 电工死亡事故是复杂的系统问题,需要从社会技术角度来看.
- 推系统思维框架用于电气行业的事故调查,政策和预防.
更多相关视频
06:00Determining The Electromyographic Fatigue Threshold Following a Single Visit Exercise Test
Published on: July 27, 2015
13.0K
11:25Identification and Quantification of Decomposition Mechanisms in Lithium-Ion Batteries; Input to Heat Flow Simulation for Modeling Thermal Runaway
Published on: March 7, 2022
5.2K
相关概念视频
Household Wiring And Electrical Safety
1.6K
Companies that supply power to most modern households use three conductors, typically called a three-wire line. While one is neutral, the other two are both at 120 V but with opposite polarity, giving a voltage of 240 V between them. With a three-wire line, high-power appliances that require 240 V, such as electric stoves and clothes dryers, are linked between the two hot lines. 120 V appliances can be connected between the neutral and either of the hot lines. The neutral side, which is always...
1.6K
Electrical Systems
696
In electrical engineering, the analysis of networks composed of passive linear components — resistors (R), capacitors (C), and inductors (L) — is fundamental. These components are organized into circuits where the relationship between input and output can be analyzed using transfer functions. The transfer function of an RLC circuit, which relates the voltage across a capacitor to the input voltage, can be derived using Kirchhoff's laws.
To derive the transfer function, consider an RLC...
To derive the transfer function, consider an RLC...
696
Power System Three-Phase Short Circuits
497
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
497
Electrical Power
3.6K
Electric power is the product of current and voltage, represented in units of joules per second, or watts. For example, cars often have one or more auxiliary power outlets with which you can charge a cell phone or other electronic devices. These outlets may be rated at 20 amps and 12 volts, so that the circuit can deliver a maximum power of 240 watts. Consider a 25 Watt bulb and a 60 Watt bulb. The conversion of electrical energy produces heat and light, while the kinetic energy lost by the...
3.6K
Reclosers and Fuses
431
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
431
Insulation Coordination
541
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
541