由IHBA优化的DR-SE-NPCNet用于在混合和噪音条件下在三级NPC逆变器中进行可靠的开放电路故障诊断
Qisheng Liu1, Changxi Chen2, Honglin Ouyang2
1College of Electrical and Information Engineering, Hunan University, Changsha, 410082, China. liuqisheng@hnu.edu.cn.
Scientific reports
|December 27, 2025
概括
本研究引入了一种新方法,用于检测三级中性点紧 (NPC) 逆变器的开放电路故障 (OCF). 综合框架提高了诊断的准确性和可靠性,即使在噪音条件下.
科学领域:
- 电气工程 电气工程
- 电力电子 电力电子 电力电子
- 人工智能的人工智能
背景情况:
- 三级中性点紧 (NPC) 逆变器的开放电路故障 (OCF) 会降低功率质量和系统可靠性.
- 现有的诊断方法在混合操作条件,高噪音水平和超参数灵敏度等方面扎.
研究的目的:
- 提出一个综合模型优化框架,用于在NPC逆变器中强大的OCF诊断.
- 在具有挑战性的环境和操作条件下提高诊断准确性和可靠性.
主要方法:
- 开发了DR-SE-NPCNet,这是一个轻量级的诊断网络,具有时间分辨率维护-时间扩张 (TRP-TD) 骨干和残余和挤压刺激校准融合 (ReSE-CF) 模块.
- 采用了改进的蜂蜜子算法 (IHBA) 进行高效和强大的全球超参数优化.
- 在硬件NPC逆变器平台上验证了框架.
主要成果:
- 在10 dB的噪音和混合操作条件下 (负载,调制指数,直流总线电压,输出频率) 达到92.83-96.94%的准确性.
- 性能优于传统的基于卷积神经网络 (CNN) 的方法.
- 通过IHBA优化,诊断准确度进一步提高了2-3%.
结论:
- 集成的DR-SE-NPCNet和IHBA框架为OCF诊断提供了一个强大的,高精度的解决方案.
- 拟议的方法有效地解决了现有诊断技术在杂和可变环境中的局限性.
相关概念视频
Bus Impedance Matrix
484
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
484
Power System Three-Phase Short Circuits
495
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
495
Three-Phase Short Circuit—Unloaded Synchronous Machine
638
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
638
Multimachine Stability
529
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
529
Line Protection with Impedance Relays
411
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
411
Fault Types
386
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
386