基于FPGA的实时DBF-SAR系统的通道间错误校准方法
Yao Meng1,2, Jinsong Qiu1,2, Pei Wang1,2
1Department of Space Microwave Remote Sensing System, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China.
Sensors (Basel, Switzerland)
|December 31, 2025
概括
本研究介绍了一种新的实时校准方法,用于数字束形合成孔径雷达 (DBF-SAR) 系统. 这种方法显著改善了信号噪声比 (SNR),并提高了数据处理,低硬件资源使用.
科学领域:
- 太空中的合成孔径雷达 (SAR) 系统
- 数字光束成形 (DBF) 技术
背景情况:
- 在SAR中进行高分辨率宽截图 (HRWS) 成像需要DBF.
- 由于硬件限制,多通道DBF-SAR系统在实时校准方面面临挑战.
研究的目的:
- 为DBF-SAR系统提出实时通道错误校准方法.
- 解决实时校准需求和有限的机载硬件资源之间的冲突.
主要方法:
- 一种基于快速里埃转换 (FFT) 脉冲压缩的实时通道误差校准方法.
- 一个"校准操作"双模式控制与参数持久性架构.
- 将高复杂度的计算与系统初始化阶段脱,以减少资源开销.
主要成果:
- 高精度补偿频道间振幅,相位和时间延迟错误.
- 在四通道系统验证中,合成的信号噪声比 (SNR) 提高了5.93dB,达到44.26dB.
- 性能接近理论上的理想收益,增强连贯的整合收益.
结论:
- 验证了DBF-SAR系统的机载实时校准与低资源消耗的可行性.
- 为下一代SAR系统的工程稳定性和高效数据处理提供关键的技术支持.
相关概念视频
Instrument Calibration
644
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
644
Calibration Curves: Correlation Coefficient
4.5K
In a linear calibration curve, there is a value called the calibration coefficient, denoted by 'r,' which measures the strength and the direction of association between two variables. The correlation coefficient value ranges from −1 to +1. A value of +1 indicates a perfect positive linear correlation, −1 denotes a perfect negative correlation, and 0 implies no correlation between the two variables. A positive correlation value establishes that as one variable increases, the...
4.5K
NMR Spectrometers: Resolution and Error Correction
1.0K
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.0K
Glassware Calibration
1.3K
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
1.3K
Bus Impedance Matrix
484
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
484


