在患有手臂振动综合征的工人中探索寒冷敏感性
S Bezanson1, A Ruco1,2,3,4, M Howse1
1Interdisciplinary Health Program, St. Francis Xavier University, Antigonish, Nova Scotia, B2G 2W5, Canada.
Occupational medicine (Oxford, England)
|December 31, 2025
概括
患有手臂振动综合征 (HAVS) 的工人经历手和脚的寒冷不耐受. 手部的症状较为严重,但脚部的症状很常见,与手部的症状有关,影响日常功能.
科学领域:
- 职业健康 职业健康 职业健康
- 血管医学 血管医学
- 神经学 神经学
背景情况:
- 手臂振动综合征 (HAVS) 主要影响上肢,对下肢功能障碍的研究有限.
- 在HAVS中血管效应是已知的功能缺陷的原因.
- 感冒不耐受和敏感性是HAVS的关键症状.
研究的目的:
- 调查患有HAVS.的工人的双手和双脚冷不耐症的流行和严重程度.
- 为了确定与HAVS患者上肢和下肢寒冷不耐受相关的因素.
主要方法:
- 采用了综合调查和回顾性图表审查方法.
- 感冒不耐受症症状严重程度 (CISS) 调查问卷适用于上肢和下肢.
- 统计分析包括斯皮尔曼相关性,威尔科克森签名等级测试和回归模型.
主要成果:
- 据报道,HAVS工作人员的脚部经常有感冒不耐受和敏感性,与手部症状相关.
- 与脚相比,手部的症状严重性得分 (CISS) 通常更高.
- 手部CISS得分的预测因素包括QuickDASH和斯德哥尔摩血管尺度;脚部CISS得分是由脚部振动暴露,脚部囊造影严重程度和QuickDASH得分预测的.
结论:
- 在患有HAVS的工人中,寒冷不耐受和敏感性表现在手和脚上.
- 综合评估和治疗两端寒冷不耐症对于改善功能结果至关重要.
- 临床医生应考虑评估和管理HAVS患者上肢和下肢症状.
相关概念视频
Local Anesthetics: Differential Sensitivity of Nerve Fibers
1.3K
Local anesthetics (LAs) block the sodium channels of nerve trunks, sensory nerve endings, and neuromuscular junctions. Although LAs can block all kinds of nerves, the sensitivity of nerve fibers differs according to nerve types and structures. LAs are known to block myelinated fibers faster than unmyelinated ones. Also, they block pain or sensory neurons at low concentrations without affecting the motor neurons involved in muscle contractions. This helps relieve labor pain without affecting the...
1.3K
Responses to Heat and Cold Stress
14.6K
Every organism has an optimum temperature range within which healthy growth and physiological functioning can occur. At the ends of this range, there will be a minimum and maximum temperature that interrupt biological processes.
14.6K
Assessment of the Cardiovascular System III: Palpation
964
Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
964
Decreased Body Temperature
954
A decreased body temperature can occur in patients with hypothermia and frostbite. Heat loss with extended cold exposure overpowers the body's ability to create heat, resulting in hypothermia. Core temperature readings help classify hypothermia. Mild hypothermia is temperatures between 32 °C (89.6 °F) and 35°C (95 °F) and is caused by impaired thermoregulation. Moderate hypothermia is temperatures between 28 C (82.4 °F) and 32 °C (89.6 °F) caused by...
954
Assessing Body Temperature - Axilla
1.1K
Procedural Guide for Assessing Axillary Body Temperature using a Digital Thermometer:
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
1.1K
Assessing Body Temperature - Oral
1.4K
Here are the steps to accurately measure oral temperature using an electronic thermometer:
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
1.4K