纠正"开发金属复合物用于使用电位计和电导计方法在片中定量化卡普托普里尔"
Badriah Saad Al-Farhan1, Anas Alfarsi2, Laila H Abdel-Rahman3
1Chemistry Department, Faculty of Girls for Science, King Khalid University, Abha 61421, Saudi Arabia.
ACS omega
|January 1, 2026
概括
这项研究纠正了先前发表的一篇文章的DOI. 校正确保了科学研究的准确引用和检索,以提高可发现性.
科学领域:
- 科学出版科学出版
- 图书统计学 图书统计学
- 研究诚信研究诚信
背景情况:
- 准确的引用对于科学完整性至关重要.
- 数字物体识别器 (DOI) 对于访问研究是必不可少的.
- 在DOI中的错误可能会阻碍研究的可访问性和影响.
研究的目的:
- 纠正一个错误的数字物体标识符 (DOI) 发表的文章.
- 确保科学文献的准确引用和检索.
- 维护研究完整性和可访问性的标准.
主要方法:
- 在原始出版物中识别错误的DOI.
- 通过出版商记录验证正确的DOI.
- 向科学界发出正式的纠正通知.
主要成果:
- 错误的DOI已被确定并纠正.
- 正确的DOI现在与该文章相关联.
- 这种纠正有助于人们不受阻碍地访问研究.
结论:
- 准确的DOI对于科学知识的传播至关重要.
- 纠正通知在维护科学记录完整性方面发挥着至关重要的作用.
- 确保正确的引用实践有助于科学的可复制性和进步.
相关概念视频
Potentiometric Titration: Overview
3.9K
Potentiometric titration is a quantitative analytical technique that determines the concentration of an analyte by measuring the potential difference between the two electrodes in the solution. The endpoint of a potentiometric titration is the point at which there is a significant change in the potential difference. It occurs when the stoichiometric reaction between the analyte and the titrant is complete. The endpoint is usually determined graphically by plotting the measured potential...
3.9K
Complexometric Titration: Ligands
2.2K
Different monodentate and polydentate ligands are used as complexing agents in complexometric titration reactions. The formation of complexes by mono- and bidentate ligands involves two or more intermediate steps, limiting their use as complexing agents. In comparison, polydentate ligands can form complexes with metal ions in a single-step process, facilitating sharper end points. This means polydentate ligands, such as amino carboxylic acid derivatives, are most commonly employed in...
2.2K
Complexometric Titration: Overview
11.0K
Complexometric titration involves the formation of a complex by reacting a metal ion with one or more ligands. A visual indicator often detects the end point of a complexometric titration. It is added to the metal solution before the titration, forming a stable metal–indicator complex and imparting color to the solution. As the titration approaches the equivalence point, the excess of the added ligand displaces the indicator from the metal–indicator complex, releasing the free...
11.0K
Controlled-Potential Coulometry: Electrolytic Methods
622
Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
The chosen potential...
622
EDTA: Auxiliary Complexing Reagents
1.2K
EDTA titrations are usually carried out in highly basic conditions, where the fully deprotonated form of EDTA, Y4−, actively complexes with the free metal ions in the solution. Several metal ions precipitate as hydrous oxide (hydroxides, oxides, or oxyhydroxides) under these conditions, lowering the concentration of free metal ions in the solution. For this reason, auxiliary complexing agents or ligands such as ammonia, tartrate, citrate, or triethanolamine are used in EDTA titrations to...
1.2K
Extraction: Advanced Methods
1.0K
Metal ions can be separated from one another by complexation with organic ligands–the chelating agent– to form uncharged chelates. Here, the chelating agent must contain hydrophobic groups and behave as a weak acid, losing a proton to bind with the metal. Since most organic ligands used in this process are insoluble or undergo oxidation in the aqueous phase, the chelating agent is initially added to the organic phase and extracted into the aqueous phase. The metal-ligand complex is...
1.0K


