高空间时空分辨率的动态亚细胞组织成像
Francesca W van Tartwijk1,2, Liuba Dvinskikh1, Edward N Ward1
11Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, United Kingdom;
Annual review of biophysics
|January 2, 2026
概括
No abstract available in PubMed .
更多相关视频
06:33Three-dimensional Imaging of Bacterial Cells for Accurate Cellular Representations and Precise Protein Localization
Published on: October 29, 2019
10.6K
08:17Probing Structural and Dynamic Properties of Trafficking Subcellular Nanostructures by Spatiotemporal Fluctuation Spectroscopy
Published on: August 16, 2021
2.1K
相关概念视频
Three-Dimensional Microscopy in Microbiology
732
Three-dimensional imaging techniques are essential in cell biology, allowing researchers to visualize intricate cellular structures with high resolution. Two prominent methods, Differential Interference Contrast Microscopy (DIC) and Confocal Scanning Laser Microscopy (CSLM), provide distinct advantages for imaging live and thick specimens, respectively.Differential Interference Contrast MicroscopyDIC microscopy enhances contrast in transparent, unstained samples by converting phase...
732
Protein Dynamics in Living Cells
2.6K
Different fluorescence-based techniques are used to study the protein dynamics in living cells. These techniques include FRAP, FRET, and PET.
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
2.6K
Super-resolution Fluorescence Microscopy
12.1K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
12.1K
