泰国人口中正常手腕参数的参考值
Sirisak Chaitantipongse1, Sutee Thaveepunsan1, Sitthiphong Suwannaphisit1
1Faculty of Medicine, Department of Orthopaedics, Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand.
The journal of hand surgery Asian-Pacific volume
|January 9, 2026
概括
这项研究确定了泰国人口的正常手腕参数参考值,揭示了基于性别的显著差异. 这些发现对于准确治疗泰国人的远半径骨折至关重要.
科学领域:
- 整形外科手术 整形外科手术
- 放射学 放射学是一门学科.
- 人类测量学 人类测量学.
背景情况:
- 放射性手腕参数对于评估远半径骨折治疗结果至关重要.
- 目前泰国人口的参考值基于西方数据,可能导致不准确.
- 距离半径的准确恢复是最佳功能恢复的关键.
研究的目的:
- 确定泰国人口关键手腕参数的规范性参考值.
- 调查这些参数中的基于性别和基于侧面的差异.
- 为临床和研究应用提供特定人群数据.
主要方法:
- 两位手术手术医生对200张前后 (PA) 和侧面手腕放射图进行分析.
- 使用中央参考点 (CRP) 测量辐射高度,辐射倾斜,肘部偏差和飞行倾斜.
- 使用类内相关系数 (ICC) 评估观察者之间的可靠性.
主要成果:
- 已确定的平均值是:辐射高度 (10.7 ± 1.3mm),辐射倾斜 (22.8° ± 2.4°),肘部偏差 (-0.2 ± 1.2mm) 和飞行倾斜 (13.5° ± 3.0°).
- 观察到基于性别的显著差异:男性的辐射高度更高;女性的辐射倾斜率更高,肘部变异和飞行倾斜.
- 对于半径倾斜 (ICC=0.92) 和肘部偏差 (ICC=0.93) 的观测者间可靠性很好;对于半径高度 (ICC=0.90) 和飞行倾斜 (ICC=0.79) 的可靠性很好.
结论:
- 已经为泰国人口建立了规范性手腕参数参考值.
- 存在显著的基于性别的差异,特别是泰国人的飞行倾斜率高于西方人群.
- 这些泰国特有的值可以增强远半径骨折治疗,植入物设计和AI数据库开发.
相关概念视频
Pre-Procedural Guidelines for Assessing Blood Pressure
807
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
807
Assessment of radial pulse
1.3K
Assessment of Radial Pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
1.3K
Assessment of blood pressure in brachial artery(one-step method)
1.1K
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
1.1K
Special considerations while measuring blood pressure
1.2K
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
1.2K
Sites for measruring blood pressure
3.3K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
3.3K
Pulse
2.0K
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
2.0K