概括
本研究介绍了一种用于非线性多元代理系统 (MAS) 的新规定的时间故障耐受性跟踪控制. 该方法确保在设定的时间内准确跟踪,即使存在不确定性和干扰.
科学领域:
- 控制系统工程 控制系统工程
- 机器人和自动化 机器人和自动化
- 网络化系统 网络化系统
背景情况:
- 非线性多代理系统 (MAS) 面临的挑战是参数不确定性和外部干扰,影响跟踪控制.
- 在MAS中实现精确和及时的控制对于许多工程应用至关重要.
- 现有的控制策略可能无法同时充分解决故障耐受性和规定的时间收.
研究的目的:
- 为非线性MAS开发一个规定的时间容错的跟踪控制策略.
- 通过重建离散的参考信号来提高追踪精度.
- 确保系统输出在特定时间内趋同到所需的轨迹,尽管存在不确定性和故障.
主要方法:
- 使用立方轴线对离散的参考信号进行插值的轨迹重建.
- 规定的时间调节器的设计,以创建一个容错的跟踪控制器.
- 使用利亚普诺夫方法和模拟示例进行稳定性分析以验证方法.
主要成果:
- 拟议的控制器确保控制系统的输出在规定的跟踪时间内以任意的精度与重建的轨迹相聚.
- 该策略有效地处理非线性MAS中的参数不确定性和外部干扰.
- 通过稳定性分析和模拟示例来证明有效性.
结论:
- 开发的规定的时间故障耐受性跟踪控制策略在理论上是合理的,并且在实践中适用.
- 该方法为非线性MAS提供了更好的跟踪精度和稳定性.
- 这项研究有助于复杂的网络系统的控制工程的进步.
相关概念视频
Feedback control systems
685
Feedback control systems are categorized in various ways based on their design, analysis, and signal types.
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
685
Linear Approximation in Time Domain
340
Nonlinear systems often require sophisticated approaches for accurate modeling and analysis, with state-space representation being particularly effective. This method is especially useful for systems where variables and parameters vary with time or operating conditions, such as in a simple pendulum or a translational mechanical system with nonlinear springs.
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
340
Time-Domain Interpretation of PD Control
370
Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Consider the example of control of motor torque. Initially, a positive...
370
Time and frequency -Domain Interpretation of Phase-lead Control
424
Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
424
PD Controller: Design
615
In automotive engineering, car suspension systems often employ Proportional Derivative (PD) controllers to enhance performance. PD controllers are utilized to adjust the damping force in response to road conditions. A controller, acting as an amplifier with a constant gain, demonstrates proportional control, with output directly mirroring input.
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
615
Time and frequency -Domain Interpretation of PI Control
392
Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
392