相关实验视频
Updated: Jan 18, 2026

08:14
Atom Probe Tomography Analysis of Exsolved Mineral Phases
Published on: October 25, 2019
7.7K
热立方体:软件工具分析外部收集的共振离子的选择性时间概述
Timothy P Cleland1, Michael G Trizna2
1Museum Conservation Institute, Smithsonian Institution, Suitland, Maryland 20746, United States.
Journal of the American Society for Mass Spectrometry
|January 16, 2026
概括
疗足软件能够对共振离子进行选择性时间概述 (STORI) 分析,以表征单个和混合蛋白质形式. 该工具准确计算未充电的蛋白质质量,并从质谱数据中识别翻译后的修改.
科学领域:
- 质谱测量质量谱测量
- 蛋白质组学是指蛋白质组学.
- 计算生物学 计算生物学
背景情况:
- 电荷检测质谱法 (CDMS) 允许对单个蛋白质形式进行表征.
- 轨道式质谱仪被广泛用于收集离子数据.
- 对复杂的蛋白形混合物的分析需要先进的计算工具.
研究的目的:
- 介绍Theropod,一种用于分析质谱过渡的新型软件套件.
- 为了实现对共振离子 (STORI) 分析的选择性时间概述.
- 为了方便计算未充电的质量和识别翻译后的修改.
主要方法:
- 开发用于STORI分析的Theropod软件工具.
- 使用外部数字示波器收集的瞬态.
- 应用宽电荷校正方法来计算质量.
主要成果:
- 成功计算了无素,肌球蛋白,碳酸无水酶和乙醇酶的未充电质量.
- 描述了皮尔斯完整蛋白质标准混合物.
- 在单个蛋白质和混合物中确定了翻译后的修改.
结论:
- 使用CDMS数据,Theropod提供了一种可靠的蛋白形体表征方法.
- 该软件有助于精确的质量测定和PTM识别.
- 热足动物是蛋白质组学研究的宝贵工具,公开提供.
相关概念视频
Mass Analyzers: Common Types
1.4K
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
1.4K
Mass Analyzers: Overview
1.6K
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
1.6K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
666
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
666
Mass Spectrum: Interpretation
2.7K
An unknown compound can be established by identifying the molecular ion peak in the mass spectrum. The molecular ion peak is often weak or absent due to the predominance of fragmentation in high-energy electron beams. In such cases, a soft-energy electron beam can be used to scan the spectrum to enhance the intensity of the molecular ion peak. Additionally, chemical ionization, field ionization, and desorption ionization spectra are used to obtain a relatively intense molecular ion peak.To...
2.7K
Double Resonance Techniques: Overview
707
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Spin decoupling is usually achieved by...
707
Tandem Mass Spectrometry
2.3K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
2.3K