新且实用的光谱测量方法用于用p-二甲基亚胺二甲酸试剂系统增强染色胺酸来确定尿素
1Operational and Quality Control Laboratories Sectors, Abu Qir Fertilizers and Chemicals Industries Company, PO Box 21911, Alexandria, Egypt.
Analytica chimica acta
|January 16, 2026
概括
使用p-二甲基亚胺甲基和染色酸的新双反应物光谱法改善了尿素的确定. 这种可靠的方法为临床和环境分析提供了更高的稳定性和准确性.
科学领域:
- 分析化学 分析化学
- 环境科学 环境科学
背景情况:
- 精确的尿素测定对于临床诊断,工业过程和环境监测至关重要.
- 使用p-dimethylaminobenzaldehyde (PDAB) 的传统光谱法面临着试剂稳定性和可重复性方面的挑战.
研究的目的:
- 开发一种稳定且可重复的光谱光度计方法来量化尿素.
- 克服现有的基于PDAB的尿素分析的局限性.
主要方法:
- 采用了一种新的双反应器系统,将PDAB和染色酸的二盐结合起来.
- 使用中央复合设计 (CCD) 和响应表面方法 (RSM) 优化了试剂组成.
- 方法验证遵循水和废水检查标准方法,第1040部分.
主要成果:
- 最优化的方法显示出强烈的线性 (R2>0.99) 到33.30mM.
- 实现了低检测 (0.34 mM) 和定量 (0.83 mM) 的极限.
- 证实了高恢复率 (90-110%) 和优异的精度 (RSD ≤6%).
结论:
- 开发的双反应剂方法为尿素光谱测量量提供了稳定,可靠和简化的方法.
- 它有效地解决了传统PDAB方法的缺点,改善了各种矩阵中的分析性能.
更多相关视频
08:31Optimized Griess Reaction for UV-Vis and Naked-eye Determination of Anti-malarial Primaquine
Published on: October 11, 2019
10.9K
12:47Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
9.9K
相关概念视频
Titration of a Weak Acid with a Weak Base
4.8K
Weak acids and bases do not undergo dissociation completely, and titrations between these two are rarely studied. When such studies are performed, say, for the titration of a weak acid with a weak base, the titration curve plots the change in pH as a function of the volume of base added. Take the titration of acetic acid with ammonia, for instance. During the titration, these two species form ammonium acetate and water, but the pH change is slow and gradual.
As a result, there is no simple...
As a result, there is no simple...
4.8K
Titration of a Weak Base with a Strong Acid
8.5K
The titration curve of a weak base like ammonia with a strong acid like hydrochloric acid is the mirror image of the titration curve of a weak acid with a strong base.
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
8.5K
Amines to Sulfonamides: The Hinsberg Test
4.4K
The Hinsberg test is a method to identify primary, secondary and tertiary amines, named after its pioneer, Oscar Hinsberg. Here, amines are treated with benzenesulfonyl chloride, also known as the Hinsberg reagent, in the presence of an excess of aqueous base, followed by acidification. Based on the nature of the amines, different changes are observed.
Generally, a primary amine reacts with the Hinsberg reagent to produce an N-substituted benzenesulfonamide. The electron-withdrawing sulfonyl...
Generally, a primary amine reacts with the Hinsberg reagent to produce an N-substituted benzenesulfonamide. The electron-withdrawing sulfonyl...
4.4K
Atomic Absorption Spectroscopy: Lab
1.0K
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
1.0K
UV–Vis Spectrometers
3.4K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
3.4K
Precipitation Titration: Endpoint Detection Methods
5.3K
In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
In the Volhard method, a standard excess of AgNO3 is first added to the...
5.3K
