Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Data Reporting and Recording01:24

Data Reporting and Recording

5.4K
Reporting and recording are crucial in data documentation. The timely, thorough, and accurate documentation of facts is essential when recording patient data. Failure to record findings during an assessment or interpretation of a problem will result in loss of information and make the patient document unreliable. The reader is left with general impressions if the information is not specific. A recording is documenting data of the individual's health information in a traceable, secure, and...
5.4K
Uncertainty in Measurement: Accuracy and Precision03:37

Uncertainty in Measurement: Accuracy and Precision

100.5K
Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value. 
100.5K
Improving Translational Accuracy02:07

Improving Translational Accuracy

14.1K
Base complementarity between the three base pairs of mRNA codon and the tRNA anticodon is not a failsafe mechanism. Inaccuracies can range from a single mismatch to no correct base pairing at all. The free energy difference between the correct and nearly correct base pairs can be as small as 3 kcal/ mol. With complementarity being the only proofreading step, the estimated error frequency would be one wrong amino acid in every 100 amino acids incorporated. However, error frequencies observed in...
14.1K
Improving Translational Accuracy02:07

Improving Translational Accuracy

3.6K
3.6K
Accuracy and Precision01:52

Accuracy and Precision

14.6K
Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value.  Highly accurate...
14.6K
Nursing Implementation01:15

Nursing Implementation

6.0K
Implementation is the execution of the nursing care plan developed during the planning phase.
The five steps to implementing effective nursing care include reassessing the patient, reviewing and revising the existing nursing care plan, organizing the resources and care delivery, anticipating and preventing complications, and implementing nursing interventions.
6.0K

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Efficacy of saline tract sealing after CT-Guided lung biopsy: a systematic review and meta-analysis.

Clinical radiology·2026
Same author

Internet image search for musculoskeletal neoplasms: do results return the correct MR sequences?

Clinical radiology·2026
Same author

Magnetic resonance neurography: part 2- interpretation decoded: a guide to Neuropathy Score Reporting and Data System and imaging signs for efficient diagnosis of peripheral nerve lesions.

Clinical radiology·2026
Same author

Magnetic Resonance Neurography (MRN): part 1- basic concepts, technical considerations, interpretation, and clinical utility.

Clinical radiology·2026
Same author

Micronutrients Levels and Their Association with Osteoporosis and Depression in Elderly Hypertensive Patients: A Case-Control Study.

La Clinica terapeutica·2026
Same author

Effects of lysophosphatidylcholine on the oxidative burst response, inflammatory cytokine secretion, and <i>Escherichia coli</i> killing in polymorphonuclear neutrophils isolated from Holstein heifer calves.

JDS communications·2026
Same journal

Structural intracranial abnormalities and brain volumes in foetuses with congenital heart disease.

Clinical radiology·2026
Same journal

Reference value of left ventricular myocardial strain by computed tomography feature tracking in healthy adults.

Clinical radiology·2026
Same journal

Semiautomated magnetic resonance imaging-based breast density measurement from routine sequences: comparison with mammography.

Clinical radiology·2026
Same journal

Where can we improve? An evaluation of discrepancies between radiology resident and consultant reports for noncontrast head computed tomography (NCHCT) scans in the emergency department at a tertiary care centre.

Clinical radiology·2026
Same journal

Proton beam therapy: neuroradiology considerations and challenges.

Clinical radiology·2026
Same journal

Weight-based contrast media volume reduction in lower limb computed tomography angiography: a prospective feasibility study.

Clinical radiology·2026
查看所有相关文章

相关实验视频

Updated: Jan 24, 2026

The Participant-Reported Implementation Update and Score PRIUS: A Novel Method for Capturing Implementation-Related Data Over Time
06:05

The Participant-Reported Implementation Update and Score PRIUS: A Novel Method for Capturing Implementation-Related Data Over Time

Published on: February 19, 2021

1.6K

软组织瘤报告和数据系统 (ST-RADS):未来的实施和诊断准确性

A Zhu1, E Mesarick1, Y Mian1

  • 1UT Southwestern Medical School, Dallas, TX, USA.

Clinical radiology
|January 22, 2026
PubMed
概括
此摘要是机器生成的。

与传统方法相比,软组织瘤报告和数据系统 (ST-RADS) 显著提高了软组织瘤的诊断准确性. 这种标准化的方法提高了肌肉骨病变的分类和管理.

更多相关视频

Implementation of Minimally Invasive Brain Tumor Resection in Rodents for High Viability Tissue Collection
08:23

Implementation of Minimally Invasive Brain Tumor Resection in Rodents for High Viability Tissue Collection

Published on: May 9, 2022

4.9K
Establishment of a Primary Culture of Patient-derived Soft Tissue Sarcoma
07:55

Establishment of a Primary Culture of Patient-derived Soft Tissue Sarcoma

Published on: April 11, 2018

14.9K

相关实验视频

Last Updated: Jan 24, 2026

The Participant-Reported Implementation Update and Score PRIUS: A Novel Method for Capturing Implementation-Related Data Over Time
06:05

The Participant-Reported Implementation Update and Score PRIUS: A Novel Method for Capturing Implementation-Related Data Over Time

Published on: February 19, 2021

1.6K
Implementation of Minimally Invasive Brain Tumor Resection in Rodents for High Viability Tissue Collection
08:23

Implementation of Minimally Invasive Brain Tumor Resection in Rodents for High Viability Tissue Collection

Published on: May 9, 2022

4.9K
Establishment of a Primary Culture of Patient-derived Soft Tissue Sarcoma
07:55

Establishment of a Primary Culture of Patient-derived Soft Tissue Sarcoma

Published on: April 11, 2018

14.9K

科学领域:

  • 肌肉骨放射学 肌肉骨放射学
  • 在瘤学瘤学.
  • 医疗成像医学成像

背景情况:

  • 软组织瘤的传统描述性报告缺乏标准化.
  • 准确的分类对于适当的患者管理和治疗计划至关重要.

研究的目的:

  • 评估ST-RADS评分系统的临床性能.
  • 将ST-RADS的诊断准确性与软组织瘤的传统描述性报告进行比较.

主要方法:

  • 未来将ST-RADS在电子发言系统中的应用.
  • 经过培训的肌肉骨放射科医生分类了236个连续的软组织瘤.
  • 在ST-RADS和使用McNemar测试的描述性报告之间比较了诊断准确性.

主要成果:

  • ST-RADS显示出优越的整体诊断准确性 (99.15%与92.80%相比,p=0.000).
  • 对于良性瘤 (ST-RADS I-III),ST-RADS实现了100%的准确性.
  • 对于恶性瘤 (ST-RADS IV-VI),ST-RADS的准确性更高 (96.74%与89.13%).

结论:

  • 未来使用ST-RADS显著提高了软组织瘤的诊断准确性.
  • ST-RADS提供了一个标准化的分类方法和管理建议.
  • 建议对ST-RADS进行更广泛的临床实施,以改善患者的治疗结果.