连续使用 - 灭菌周期对ProTaper终极文件的机械和热影响:一个具有实际影响的体外评估
Helena Khidr1, Amre R Atmeh2, Mohamed Jamal1
1Endodontic Department, Hamdan Bin Mohammed College of Dental Medicine, Mohammed Bin Rashid University of Medicine and Health Sciences, Dubai Health, Dubai, United Arab Emirates.
Journal of endodontics
|January 22, 2026
概括
重复使用和自灭菌显著降低了热处理- (NiTi) 旋转文件的循环疲劳阻力. 这种不良影响随着使用周期的增加而增加,从而影响曲线根通道中的文件耐用性.
科学领域:
- 牙周内科医院 牙周内科医院 牙周内科医院
- 材料科学 材料科学 材料科学
背景情况:
- 循环疲劳失败是曲根管中旋转内牙科文件的主要关注点.
- 热处理的- (NiTi) 文件提供了更好的灵活性和对循环疲劳的抵抗力.
研究的目的:
- 为了评估重复使用和自闭体灭菌对ProTaper Ultimate (PT-U) NiTi文件的动态循环疲劳阻力的影响.
- 为了评估这些文件在J形运河中模拟使用后的耐用性.
主要方法:
- 180个新的ProTaper Ultimate (PT-U) NiTi文件 (Slider,Shaper,F1,F2) 被分为新,两用和四用组.
- 文件被用来准备模拟的J形道,并在使用之间通过自闭槽进行消毒.
- 进行了动态循环疲劳测试,以确定平均周期到故障 (NCF).
主要成果:
- 在所有组中,Slider文件的NCF明显高于Shaper,F1和F2文件.
- 重复使用和灭菌周期逐渐降低了所有测试的PT-U文件的循环疲劳抵抗力.
- 在使用和绝育四个周期后,观察到NCF显著减少.
结论:
- 重复的临床使用和自闭体灭菌显著损害了新型热处理NiTi文件的循环疲劳抵抗力.
- 使用/消毒周期增加和文件性能降低 (NCF) 之间存在直接相关性.
- 临床医生应考虑重新消毒的内牙科文件的疲劳抵抗力降低.
相关概念视频
Cleaning, Sterilization, and Disinfection
9.7K
Cleaning, disinfection, and sterilization are the methods that help to break the infection chain and prevent disease.
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
9.7K
Methods of Sterilization II: Chemical Methods
8.9K
In healthcare, the chemical method of sterilization uses chemical sterilants to treat surgical instruments and medical supplies to help prevent the transmission of infectious pathogens to patients. Due to heat sensitivity, most medical supplies and equipment should not be exposed to high temperatures. These parts include rubber, plastic, glass, and other similar elements.
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
8.9K
What are Biogeochemical Cycles?
39.2K
The most common elements in organic molecules, carbon, hydrogen, oxygen, nitrogen, sulfur, and phosphorus, are only available in the ecosystem in limited amounts. Therefore, these nutrients must be recycled through both biotic and abiotic components of the ecosystem, in processes generally called biogeochemical cycles.
39.2K
The Water Cycle
28.2K
The Earth’s hydrosphere includes all of the areas where the storage and movement of water occurs. Since water is the basis of all living processes, the cycling of water is extremely important to ecosystem dynamics.
28.2K
Impact of Groups on Groups
236
Social psychologists analyze how groups influence one another, shaping social structures and interactions through both cooperation and competition. These dynamics manifest in various ways, ranging from economic partnerships to intergroup conflicts that shape societal structures and perceptions.Cooperation and Competition in Intergroup RelationsIntergroup relationships vary across contexts, sometimes fostering cooperation and mutual benefit while at other times leading to conflict and...
236
Thermal expansion and Thermal stress: Problem Solving
2.1K
San Francisco's Golden Gate Bridge is exposed to temperatures ranging from -15 °C to 40 °C. At its coldest, the main span of the bridge is 1275 m long. Assuming that the bridge is made entirely of steel, what is the change in its length between these temperatures?
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
2.1K