相关实验视频
Updated: Jan 24, 2026

05:39
Dermoscopy Aids in the Diagnosis of Discoid Lupus Erythematosus
Published on: May 16, 2025
589
Telitacicept用于系统性红斑狼相关的外周神经病变:一个病例报告
Jinhui Tan1, Hai Huang2, Linghua Tan3
1People's Hospital of Longhua, Shenzhen, Guangdong, China.
Frontiers in immunology
|January 23, 2026
概括
在患有全身性红斑狼 (SLE) 的患者中,Telitacicept有效治疗了外围神经病变. 这种新型疗法为传统治疗方法 (如环胺) 提供了更安全的替代方案,特别适用于生育年龄的女性.
科学领域:
- 类风湿病学 类风湿病学
- 神经学 神经学
- 免疫学 免疫学 免疫学
背景情况:
- 周围神经病变 (PN) 是系统性红斑狼 (SLE) 的复杂并发症.
- 像葡萄糖皮质类药物和环胺 (CYC) 等常规治疗对年轻女性具有重大风险,包括淋巴腺毒性.
- 有限的基于证据的指导方针存在,用于管理与SLE相关的PN.
研究的目的:
- 报告telitacicept的成功使用,它是B-淋巴细胞刺激剂 (BLyS) 和增殖诱导配体 (APRIL) 的双重抑制剂,在患有SLE相关PN的患者中成功使用.
- 评估telitacicept作为一种用于SLE-PN管理的类固醇节约和更安全的替代品.
主要方法:
- 一个37岁的女性病例报告,她有17年的SLE和狼性炎病史,患上PN.
- 治疗包括将皮下注射的特利塔西塞普 (telitacicept) (160 mg/周) 添加到现有的普雷尼松和甲酸莫菲提尔 (MMF) 治疗中.
- 在治疗前和治疗后进行临床和电生理学评估.
主要成果:
- 在telitacicept开始的几个月内,神经病症症状 (麻木,低感觉) 完全消失.
- 炎症标志物 (ESR,hs-CRP) 和补充水平的正常化,蛋白尿尿减少.
- 可以显著降低普得尼松和MMF的剂量,在八个月的电肌图检测结果正常.
结论:
- 泰利塔西塞普在治疗SLE相关PN方面表现出高疗效,这是该适应症的首次报告使用.
- 它作为一种强效的,节省类固醇的,更安全的环胺替代品,特别适用于生育年龄的患者.
- 需要进一步的研究来探索特利塔西塞普的作用,并将其与免疫检查点抑制剂相关的神经病变进行比较.
相关概念视频
Data Reporting and Recording
5.4K
Reporting and recording are crucial in data documentation. The timely, thorough, and accurate documentation of facts is essential when recording patient data. Failure to record findings during an assessment or interpretation of a problem will result in loss of information and make the patient document unreliable. The reader is left with general impressions if the information is not specific. A recording is documenting data of the individual's health information in a traceable, secure, and...
5.4K
Types of Reports I: Hands-off Report
1.5K
A hand-off report, also known as a change-of-shift report, is a crucial nursing process that ensures the smooth transition of patient care responsibilities between nursing staff.
Following are the key components and categories of hand-off reports:
Purpose and Process:
Following are the key components and categories of hand-off reports:
Purpose and Process:
1.5K
Second Order systems II
394
In an underdamped second-order system, where the damping ratio ζ is between 0 and 1, a unit-step input results in a transfer function that, when transformed using the inverse Laplace method, reveals the output response. The output exhibits a damped sinusoidal oscillation, and the difference between the input and output is termed the error signal. This error signal also demonstrates damped oscillatory behavior. Eventually, as the system reaches a steady state, the error diminishes to zero.
394
Types of Reports II: Incident or Occurrence Report
1.2K
An Incident or Occurrence Report in a healthcare setting is a crucial document used to record any unexpected occurrence that may or may not have affected a patient, employee, or visitor. Such reports are critical to improving patient safety and include all details leading up to and including the event.
Purposes:
In the healthcare industry, reports play a crucial role in documenting incidents within an agency. The primary objective of these reports is to ensure patient safety, uphold the...
Purposes:
In the healthcare industry, reports play a crucial role in documenting incidents within an agency. The primary objective of these reports is to ensure patient safety, uphold the...
1.2K
First Order Systems
411
First-order systems, such as RC circuits, are foundational in understanding dynamic systems due to their straightforward input-output relationship. Analyzing their responses to different input functions under zero initial conditions reveals significant insights into system behavior.
When a first-order system is subjected to a unit-step input, its response is characterized by its transfer function. By applying the Laplace transform of the unit-step input to the transfer function, expanding the...
When a first-order system is subjected to a unit-step input, its response is characterized by its transfer function. By applying the Laplace transform of the unit-step input to the transfer function, expanding the...
411
Second Order systems I
580
A servo system exemplifies a second-order system, featuring a proportional controller and load elements that ensure the output position aligns with the input position. The relationship between these components is described by a second-order differential equation. Applying the Laplace transform under zero initial conditions yields the transfer function, showing how inputs are converted to outputs in the system.
By reinterpreting the system, one can derive the closed-loop transfer function, which...
By reinterpreting the system, one can derive the closed-loop transfer function, which...
580

