在72小时内首次不能动员到重症监护室的病人,脑部区域氧和度较低
Ryota Imai1, Atsuhiro Tsubaki2, Takafumi Abe1
1Department of Rehabilitation, Uonuma Kikan Hospital, Minamiuonuma, Japan.
Advances in experimental medicine and biology
|January 23, 2026
概括
在ICU的早期动员改善了结果. 区域大脑氧和 (rSO2) 监测可能有助于确定患者动员的最佳时间,从而有可能改善恢复.
科学领域:
- 密集护理医学 密集护理医学
- 神经科学是一个神经科学.
- 医疗技术 医疗技术 医学技术
背景情况:
- 在ICU入院后72小时内早期动员与更好的患者结果有关.
- 通过近红外光谱学 (NIRS) 测量区域大脑氧和 (rSO2),越来越多地被认为具有预测价值.
研究的目的:
- 根据患者在ICU调动的时间,调查rSO2值的差异.
- 评估rSO2是否可以指导重症患者调动的时间.
主要方法:
- 80名ICU患者被分为早期动员 (EM) 和非早期动员 (非EM) 组.
- 在动员期间使用NIRS监测了前额前部rSO2.
- 分析了患者的背景和第一次动员的时间.
主要成果:
- 在EM和非EM组之间观察到患者背景的显著差异.
- 最低的rSO2值发生在末端坐着时,与EM组相比 (58.6 ± 4.3%),非EM组的值明显较低 (56.5 ± 4.8%).
- 在rSO2和第一次动员的几天之间发现了弱负相关性 (r = -0.251,p = 0.025).
结论:
- 在调动期间的rSO2值在早期调动的患者和后来调动的患者之间有所不同.
- 在非EM组中较低的rSO2值表明潜在的大脑低 perfusion 或对调动不耐受.
- rSO2可以作为优化ICU患者调动时间的有价值标志物.
相关概念视频
Special considerations while measuring oxygen saturation
930
Assessing respiratory rate concurrently with pulse measurement is fundamental to patient care, providing valuable insights into the patient's respiratory function. The normal breathing rate for an adult usually falls within a normal range of 12 to 20 breaths per minute. Abnormal respiratory rates can signal underlying health conditions or the need for immediate intervention.
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
930
Solution Equilibrium and Saturation
21.6K
Imagine adding a small amount of sugar to a glass of water, stirring until all the sugar has dissolved, and then adding a bit more. You can repeat this process until the sugar concentration of the solution reaches its natural limit, a limit determined primarily by the relative strengths of the solute-solute, solute-solvent, and solvent-solvent attractive forces. You can be certain that you have reached this limit because, no matter how long you stir the solution, undissolved sugar remains. The...
21.6K
Holter Monitor: 24-Hour Monitoring
2.3K
Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
2.3K
IR Frequency Region: Fingerprint Region
1.9K
IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the...
1.9K
The Eukaryotic Promoter Region
18.7K
The eukaryotic promoter region is a segment of DNA located upstream of a gene. It contains an RNA polymerase binding site, a transcription start site, and several cis-regulatory sequences. The proximal promoter region is located in the vicinity of the gene and has cis-regulatory sequences and the core promoter. The core promoter is the binding site for RNA polymerase and is usually located between -35 and +35 nucleotides from the transcription start site. The distal promoter regions are...
18.7K
Region of Convergence
909
The z-transform is a powerful mathematical tool used in the analysis of discrete-time signals and systems. It is a crucial tool in the analysis of discrete-time systems, but its convergence is limited to specific values of the complex variable z. This range of values, known as the Region of Convergence (ROC), is fundamental in determining the behavior and stability of a system or signal. The ROC defines the region in the complex plane where the z-transform converges, which can take various...
909