概括
网站特定脉冲激光化 (SSPLA) 精确地修改二维过渡金属二甲基化物 (TMD) 超薄膜. 这种方法提高了二硫化 (MoS2) 装置的电气和结构性能,降低了电阻的多达四倍.
科学领域:
- 材料科学 材料科学 材料科学
- 纳米技术纳米技术
- 半导体加工 半导体加工
背景情况:
- 像二硫化物 (MoS2) 这样的二维 (2D) 过渡金属二甲基化物 (TMD) 对下一代电子产品至关重要.
- 改善这些材料的结构和电气性能对于设备的性能至关重要.
- 修改TMD的现有方法往往缺乏精度,并可能导致热损伤.
研究的目的:
- 报告一个精确的,非热的,超短脉冲激光工艺,用于选择性结构修改2DTMDs.
- 为了证明特定站点脉冲激光化 (SSPLA) 在增强CVD培养的MoS2薄膜设备中的有效性.
- 研究MoS2.2中激光诱导结晶的潜在机制.
主要方法:
- 使用超短脉冲激光火,脉冲的空间重叠很高.
- 在SiO2-Si基板上的MoS2薄膜上应用低于损伤值 (<12mJ cm−2) 的激光流动.
- 采用激光光束扫描技术在环境空气中进行特定地点的处理.
主要成果:
- 拉曼光谱证实了无形MoS2.2的转化为晶体MoS2.
- 在SSPLA后,设备电阻降低了多达四倍.
- 横截面STEM显示膜稀释和改善结晶;AFM显示粒度扩大.
结论:
- SSPLA是一种有效的技术,用于精确地,局部地提高MoS2薄膜的结构和电气性能.
- 结晶似乎是通过低温固态扩散发生的.
- SSPLA工艺适用于可扩展,精密的后端半导体晶圆制造.
更多相关视频
08:53Dependence of Laser-induced Breakdown Spectroscopy Results on Pulse Energies and Timing Parameters Using Soil Simulants
Published on: September 23, 2013
11.7K
08:48Selective Area Modification of Silicon Surface Wettability by Pulsed UV Laser Irradiation in Liquid Environment
Published on: November 9, 2015
8.6K
相关概念视频
Pulse
2.0K
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
2.0K
Pulse
3.5K
The pulse is one of the most fundamental physiological indicators of the body's cardiovascular health. It is the rhythmic expansion and contraction of the arterial walls in response to the pressure generated by the heart's pumping action.
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
3.5K
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
1.7K
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
1.7K
Pulse Oximetry
1.3K
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
1.3K
Regulation of Pulse
2.3K
Pulse regulation involves physiological mechanisms that ensure adequate blood flow throughout the body. The heartbeat, regulated by the autonomic nervous system, is influenced by hormonal balance, physical activity, and emotional state.
2.3K
Pulse rhythm
1.4K
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
1.4K