Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Oxidation-Reduction Reactions03:11

Oxidation-Reduction Reactions

75.5K
Oxidation–Reduction Reactions
75.5K
Block Diagram Reduction01:22

Block Diagram Reduction

552
The process of deriving the transfer function of a control system often involves reducing its block diagram to a single block. This simplification can be achieved through a series of strategic operations, including relocating branch points and comparators. These operations preserve the overall function of the system while allowing for easier manipulation and combination of blocks.
The first step in this process is the identification and relocation of a branch point. A branch point, where a...
552
Oxymercuration-Reduction of Alkenes02:36

Oxymercuration-Reduction of Alkenes

9.3K
Oxymercuration–reduction of alkenes is one of the major reactions converting alkenes to alcohols. It involves the hydration of alkenes with mercuric acetate in a mixture of tetrahydrofuran and water, forming an organomercury adduct. This is followed by a demercuration step in which the adduct is reduced to an alcohol using sodium borohydride.
9.3K
Radiological Investigation I: X-ray and CT01:30

Radiological Investigation I: X-ray and CT

1.1K
Radiological investigations, including X-rays and computed tomography (CT) scans, are critical for diagnosing and evaluating various medical conditions. These imaging techniques provide valuable insights into the body's internal structures, aiding in the detection of abnormalities, assessment of disease progression, and development of treatment strategies. This article delves into two primary radiological investigations, chest X-rays and CT scans, outlining their purpose, procedures, and...
1.1K
Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

852
Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
852
Phase I Reactions: Reductive Reactions01:27

Phase I Reactions: Reductive Reactions

586
Phase I biotransformation reductive reactions are chemical processes that modify drugs by introducing or revealing polar functional groups via reduction. Enzymes called reductases catalyze these reactions, playing a pivotal role in drug metabolism by transforming lipophilic drugs into more polar, water-soluble metabolites for easy excretion. An essential type of reductive reaction is the carbonyl group reduction, where aldehydes and ketones are reduced to alcohols. An example is the...
586

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Corrigendum: Measured and Monte Carlo simulated electron backscatter to the monitor chamber for the varian TrueBeam linac (2016<i>Phys. Med. Biol</i>.<b>61</b>8779).

Physics in medicine and biology·2026
Same author

A pilot study: dual-contrast arthrography using photon-counting detector computed tomography with gadolinium and iodine contrasts.

Physics in medicine and biology·2026
Same author

Hallucination at low radiation dose: Evaluation of two deep-learning reconstruction methods in high-resolution chest CT.

Proceedings of SPIE--the International Society for Optical Engineering·2026
Same author

Design of a next-generation conventional scintillator x-ray detector: Improved spatial resolution and fill factor.

Medical physics·2026
Same author

A framework for quantifying and leveraging uncertainty in pre-trained CT denoising model.

IEEE transactions on bio-medical engineering·2026
Same author

Color CT, literally.

Proceedings of SPIE--the International Society for Optical Engineering·2026

相关实验视频

Updated: Jan 28, 2026

High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT
08:57

High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT

Published on: June 21, 2011

19.2K

通过冗余采样和自校准,减少光子计数CT中的环形工件.

Scott S Hsieh, James Day, Xinchen Deng

    IEEE transactions on medical imaging
    |January 26, 2026
    PubMed
    概括

    探测器自校准通过使用两个冗余测量进行动态校准,显著减少光子计数CT (PCCT) 中的环形物. 这种方法为提高先进CT系统的图像质量提供了有前途的解决方案.

    科学领域:

    • 医疗成像医学成像
    • 物理 物理学 物理
    • 工程 工程师 工程师 工程师

    背景情况:

    • 计算机断层扫描 (CT) 中的环形物件是一个常见的问题,特别是在光子计数探测器 (PCD) 中.
    • 传统的工件减少方法涉及硬件改进或软件纠正.
    • 探测器自校准提供了一种替代方法来缓解这些工件.

    研究的目的:

    • 研究一种简化的自校准方法,只需要PCD的两个冗余采集.
    • 为了制定和测试这种自动校准技术作为一个优化问题.

    主要方法:

    • 开发了一种自校准方法,使用每个直线积分的两个冗余样本.
    • 制定了校准作为一个优化问题来确定相对增益因子.
    • 在各种幻象和大腿样本上测试了该方法,使用检测器转移进行演示.

    主要成果:

    • 在测试样本中观察到环形工件的显著减少.
    • 剩余的文物是最小的,与内在探测器的不稳定性相比较.
    • 自动校准方法在缓解PCD相关的环形工件方面被证明是有效的.

    结论:

    更多相关视频

    X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
    08:30

    X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging

    Published on: September 11, 2011

    14.9K
    A Reverse Genetic Approach to Test Functional Redundancy During Embryogenesis
    06:59

    A Reverse Genetic Approach to Test Functional Redundancy During Embryogenesis

    Published on: August 11, 2010

    12.4K

    相关实验视频

    Last Updated: Jan 28, 2026

    High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT
    08:57

    High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT

    Published on: June 21, 2011

    19.2K
    X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
    08:30

    X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging

    Published on: September 11, 2011

    14.9K
    A Reverse Genetic Approach to Test Functional Redundancy During Embryogenesis
    06:59

    A Reverse Genetic Approach to Test Functional Redundancy During Embryogenesis

    Published on: August 11, 2010

    12.4K
  • 探测器自校准为减少光子计数CT中的环形物件提供了可行的解决方案.
  • 这种技术可以降低对热管理和探测器稳定性的要求.
  • 自动校准可能会加速光子计数CT技术的临床采用.