为光伏微电网进行性能控制和实时验证的混合类Z源多输出转换器系统
Pooja Deori1, Anish Ahmad2, Abhinandan Routray3
1Department of Electrical Engineering, Tezpur University, Tezpur, 784028, India.
Scientific reports
|January 26, 2026
概括
本研究介绍了一种基于光伏的微电网新型混合转换器,在单一阶段提供同时交流/直流输出. 实时验证证实了其效率和微电网应用的复杂性降低.
科学领域:
- 电气工程 电气工程
- 可再生能源系统可再生能源系统
- 电力电子 电力电子 电力电子
背景情况:
- 传统的微电网需要多个转换器来适应交流和直流负载,导致体积大,成本更高,效率降低.
- 对于微电网来说,单阶段转换系统是理想的,以有效地满足同时的交流和直流电力需求.
研究的目的:
- 为微电网应用展示基于光伏 (PV) 的混合准Z源多输出转换器系统的实时验证.
- 引入一种新的控制策略,用于在单阶段转换器中同时调节交流和直流输出.
主要方法:
- 使用光伏阵列作为输入电源,使用基于扰动和观察的最大功率点跟踪 (MPPT) 算法.
- 开发了一个闭环控制系统,可以独立控制工作周期和AC和DC输出的调制指数.
- 在台风HIL平台上进行了详细的数学分析,模拟验证和硬件在循环 (HIL) 测试.
主要成果:
- 拟议的混合型准Z源转换器实现了对同时交流和直流输出的单阶段转换.
- 新的控制策略有效地调节了独立的交流和直流输出.
- 实时HIL验证证实了该系统对微电网应用的有效性和可行性.
结论:
- 开发的基于光伏的混合转换器为微电网电力管理提供了一个紧的,具有成本效益和高效的解决方案.
- 拟议的控制方法提供了对多个输出的精确调节,提高了微电网的稳定性和性能.
- 实时验证强调了系统对实际微电网集成的准备.
相关概念视频
Sources of Self-Esteem II: Performance Feedback
189
Self-esteem is intricately tied to our perception of competence and our ability to exert control over our lives. One of the primary sources of this perception is performance feedback — the ongoing evaluation of our actions in terms of success and failure. According to Franks and Marolla (1976), people derive self-worth from experiencing themselves as causal agents, capable of achieving goals and overcoming obstacles. This process nurtures a critical component of self-esteem:...
189
Real Time RT-PCR
65.0K
Real-time reverse transcription-polymerase chain reaction, or Real-time RT-PCR, is an analytical tool used to determine the expression level of target genes. The method involves converting mRNA to complementary DNA with the help of an enzyme known as reverse transcriptase, followed by the PCR amplification of the cDNA. These two processes can be performed simultaneously in a single tube or separately as a two-step reaction.
The real-time quantification of the number of amplified products is...
The real-time quantification of the number of amplified products is...
65.0K
Reliability and Validity
13.8K
Reliability and validity are two important considerations that must be made with any type of data collection. Reliability refers to the ability to consistently produce a given result. In the context of psychological research, this would mean that any instruments or tools used to collect data do so in consistent, reproducible ways.
13.8K
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
3.3K
Cardiac output (CO), the amount of blood the heart pumps per minute, is a parameter in cardiovascular physiology determined by stroke volume and heart rate. Stroke volume, the amount of blood pushed from one of the ventricles per heartbeat, is influenced by preload, afterload, and contractility.
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
3.3K
Hybrid Zones
21.8K
Hybrid zones are narrow regions where two closely related species interact, mate, and produce hybrids. Relative to either parent species, hybrids may possess distinct phenotypic or genetic differences that impact their survival and reproductive success. The genetic variances introduced by hybridization influence species diversity and speciation processes within the hybrid zone.
21.8K
Time-Domain Interpretation of PD Control
394
Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Consider the example of control of motor torque. Initially, a positive...
394