实验室NMR在生物医学:一个更新的文献概述
Linda Fantato1, Maria Salobehaj1, Jacopo Patrussi1
1Department of Chemistry "Ugo Schiff", University of Florence, Via della Lastruccia 3-13, 50019 Sesto Fiorentino, Italy.
Metabolites
|January 27, 2026
概括
基板核磁共振 (NMR) 谱学为临床代谢学提供了具有成本效益的解决方案. 这项技术在诊断诸如结核病和糖尿病等疾病方面表现有前途,其准确性与高场系统相美.
科学领域:
- 临床代谢组学
- 分析化学是一种分析化学.
- 生物医学研究的研究.
背景情况:
- 核磁共振 (NMR) 光谱对于代谢学至关重要,但受到成本和复杂性的限制.
- 台式NMR系统为临床和护理场所应用提供了更容易获得的替代方案.
- 本综述评估了基准NMR在临床代谢学中的潜力,与高场系统相比.
研究的目的:
- 系统地审查基板NMR光谱学的临床应用.
- 与高场NMR相比,评估它的优势,当前用途和挑战.
- 突出其在民主化代谢学中的作用.
主要方法:
- 在Web of Science和PubMed的系统文献搜索.
- 在临床/生物医学应用 (人/动物) 中包括对基板NMR的研究.
- 专注于比较性能和高级数据分析 (多变量,机器学习).
主要成果:
- 15项研究 (2018-2025) 符合标准,11项人类,4项动物.
- 基板NMR成功地区分了诸如结核病,糖尿病,败血症和病等疾病.
- 诊断准确度与高场NMR仪器相当.
结论:
- 基板NMR推进了代谢学可访问性,尽管灵敏度和分辨率较低.
- 硬件改进,先进的脉冲序列和AI集成将提高性能.
- 预计这些进展将加速对基板NMR的临床采用.
相关概念视频
NMR Spectrometers: Overview
2.2K
NMR spectrometers consist of a strong magnet, a radiofrequency transmitter, and a detector attached to a computer console for recording spectra of samples containing NMR-active nuclei. In first-generation NMR instruments called continuous-wave spectrometers, the resonance frequencies of the nuclei are determined by frequency-sweep or field-sweep methods. The magnetic field strength is fixed and the rf signal is swept in the former, while the radiofrequency signal is fixed and the magnetic field...
2.2K
Carbon-13 (¹³C) NMR: Overview
7.7K
Carbon-13 is a naturally occurring NMR-active isotope of carbon with a low natural abundance of 1.1%. In contrast, carbon-12 is the most abundant isotope of carbon with zero nuclear spin. Therefore, it is NMR inactive. The gyromagnetic ratio of carbon-13 is smaller than that of protons. As a result, carbon-13 resonance is about 6000 times weaker than proton resonance. For a given magnetic field strength, the resonance frequency of carbon-13 is about one-fourth of the resonance frequency for...
7.7K
Two-Dimensional (2D) NMR: Overview
1.5K
The 1D NMR spectrum of large and complex molecules like natural products has complicated splitting patterns and overlapping signals, which can be easily interpreted using 2-dimensional (2D) NMR. Unlike 1D NMR, 2D NMR has two frequency axes that provide the coupling information between the nucleus A and nucleus B in a molecule. The process from which 2D spectra are obtained has four steps.
The first step is the preparation period, during which nucleus A is excited with a radiofrequency pulse....
The first step is the preparation period, during which nucleus A is excited with a radiofrequency pulse....
1.5K
¹H NMR Signal Integration: Overview
3.6K
The intensity of a signal, which can be represented by the area under the peak, depends on the number of protons contributing to that signal. The area under each peak is shown as a vertical line called an integral, with the integral value listed under it, as seen in the proton NMR spectrum of benzyl acetate. Each integral value is divided by the smallest integral value to obtain the ratio of the number of protons producing each signal. The ratio reveals the relative number of protons and not...
3.6K
Nuclear Magnetic Resonance (NMR): Overview
6.8K
Nuclear magnetic resonance (NMR) is a phenomenon exhibited by certain nuclei that can absorb characteristic radio frequency radiation under certain conditions. NMR has been extensively applied in molecular spectroscopy and medical diagnostic imaging. In both these applications, the molecule or subject under study is placed in a magnetic field and irradiated with radio frequency energy.
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
6.8K
NMR Spectroscopy: Chemical Shift Overview
3.3K
The position of the absorption signal of a sample is reported relative to the position of the signal of tetramethylsilane (TMS), which is added as an internal reference while recording spectra. The difference between the absorption frequencies of the sample and TMS (in Hz) is divided by the spectrometer operating frequency (in MHz) to obtain a dimensionless quantity called the chemical shift. It is reported on the δ (delta) scale and expressed in parts per million.
For instance, the proton...
For instance, the proton...
3.3K