为儿童建立CT衍生的规范性肝脏和脏体积:在区域和国际数据集中的验证
Jae-Yeon Hwang1,2, Young Hun Choi1,2, Ah Young Jung3
1Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea.
Radiology
|January 27, 2026
概括
本研究使用CT扫描确定了儿科肝脏和脏体积的验证参考值. 与现有公式相比,新模型提高了准确性,有助于对儿童的临床评估.
科学领域:
- 放射学 放射学是一门学科.
- 儿科成像学 儿科成像学
- 医学成像分析 医学成像分析
背景情况:
- 准确的儿科肝脏和脏体积参考值是有限的,需要外部验证.
- 目前用于器官体积的儿科参考值缺乏广泛的适用性.
研究的目的:
- 为了确定儿童肝脏和脏的规范体积,使用增强对比度的CT.
- 在外部区域和国际数据集中验证这些儿科器官体积参考值.
主要方法:
- 对1298名 (2-18岁) 儿童的对比度增强CT扫描进行了回顾性分析,用于数据集导出.
- 门阶段CT图像的自动细分与手动校正.
- 使用来自区域 (首尔) 和国际 (辛辛那提) 儿童医院的数据集进行验证.
主要成果:
- 结合性别,身高和体重的定量回归模型显示,对于第50百分位肝脏和脏体积的最佳预测性能.
- 与此前在区域验证中公布的公式相比,开发的模型显示了更好的准确性 (较低的平均平球损失).
- 外部国际验证证实可比的绝对误差和较低的平均平球损失用于预测第50百分位数的体积.
结论:
- 儿童的肝脏和脏规范体积使用量子回归模型成功得出.
- 该研究提出了一种经过验证的模型,用于儿科器官体积测量,其预测性能得到改善.
- 这些发现为评估儿科患者肝脏和脏大小提供了更准确的工具.
相关概念视频
Internal Receptors
74.6K
Many cellular signals are hydrophilic and therefore cannot pass through the plasma membrane. However, small or hydrophobic signaling molecules can cross the hydrophobic core of the plasma membrane and bind to internal, or intracellular, receptors that reside within the cell. Many mammalian steroid hormones use this mechanism of cell signaling, as does nitric oxide (NO) gas.
74.6K
Reliability and Validity
13.8K
Reliability and validity are two important considerations that must be made with any type of data collection. Reliability refers to the ability to consistently produce a given result. In the context of psychological research, this would mean that any instruments or tools used to collect data do so in consistent, reproducible ways.
13.8K
Internal Energy
36.7K
The total of all possible kinds of energy present in a substance is called the internal energy (U), sometimes symbolized as E. Suppose a system with initial internal energy, Uinitial, undergoes a change in energy (transfer of work or heat), and the final internal energy of the system is Ufinal. Change in internal energy equals the difference between Ufinal and Uinitial.
36.7K
Constant Volume Calorimetry
30.7K
Calorimeters are useful to determine the heat released or absorbed by a chemical reaction. Coffee cup calorimeters are designed to operate at constant (atmospheric) pressure and are convenient to measure heat flow (or enthalpy change) accompanying processes that occur in solution at constant pressure. A different type of calorimeter that operates at constant volume, colloquially known as a bomb calorimeter, is used to measure the energy produced by reactions that yield large amounts of heat and...
30.7K
Real Gases: Effects of Intermolecular Forces and Molecular Volume Deriving Van der Waals Equation
39.0K
Thus far, the ideal gas law, PV = nRT, has been applied to a variety of different types of problems, ranging from reaction stoichiometry and empirical and molecular formula problems to determining the density and molar mass of a gas. However, the behavior of a gas is often non-ideal, meaning that the observed relationships between its pressure, volume, and temperature are not accurately described by the gas laws.
39.0K
IR Frequency Region: Fingerprint Region
1.9K
IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the...
1.9K


