转变中的结肠镜质量指标:从腺瘤检测率到状损伤检测和超越
Aryan Jain1, James Javier1, Kyle Nguyen-Ngo1
1Department of Gastroenterology, Albany Medical College, Albany, NY 12208, USA.
Diagnostics (Basel, Switzerland)
|January 28, 2026
概括
结肠镜质量正在提高,新的指标超出了腺瘤检测率 (ADR),如状息肉检测率 (SPDR),以更好地检测所有结肠直肠癌 (CRC) 病变,包括状类型.
科学领域:
- 胃肠病学 胃肠病学
- 内镜检查是指内镜检查.
- 结肠直肠癌 预防 预防
背景情况:
- 腺瘤检测率 (ADR) 是预防结肠直肠癌 (CRC) 的关键结肠镜质量基准.
- 单独的ADR是不够的,因为状瘤的途径对CRC有显著的贡献.
- 新的指标正在出现,比如静态聚体检测率 (SPDR) 和每次结肠镜检查的腺瘤 (APC).
研究的目的:
- 探索结肠镜检查质量指标的演变,超越ADR.
- 强调补充指标对于检测多种结直肠瘤的重要性.
- 讨论技术进步在改善病变检测中的作用.
主要方法:
- 审查当前文学和质量基准在结肠镜检查.
- 讨论新兴指标 (SPDR,APC) 及其挑战.
- 探索提高病变检测的技术进步.
主要成果:
- SPDR和APC为检测状病变提供了优势,但面临着诸如变异性和缺乏标准化的挑战.
- 技术进步改善了微妙病变的检测,并减少了变异性.
- 在大型注册表中正在开发集成ADR,SPDR和APC的复合模型.
结论:
- 结肠镜质量评估正在超越ADR发展,包括解决状病变的指标.
- 标准化和培训对于有效实施新指标至关重要.
- 未来的质量评估可能将涉及复合模型,反映全面的瘤检测.
相关概念视频
Indicators
60.5K
Certain organic substances change color in dilute solution when the hydronium ion concentration reaches a particular value. For example, phenolphthalein is a colorless substance in any aqueous solution with a hydronium ion concentration greater than 5.0 × 10−9 M (pH < 8.3). In more basic solutions where the hydronium ion concentration is less than 5.0 × 10−9 M (pH > 8.3), it is red or pink. Substances such as phenolphthalein, which can be used to determine the pH of a solution, are...
60.5K
Phase Transitions
23.1K
Whether solid, liquid, or gas, a substance's state depends on the order and arrangement of its particles (atoms, molecules, or ions). Particles in the solid pack closely together, generally in a pattern. The particles vibrate about their fixed positions but do not move or squeeze past their neighbors. In liquids, although the particles are closely spaced, they are randomly arranged. The position of the particles are not fixed—that is, they are free to move past their neighbors to...
23.1K
Endoscopic Procedures II: Colonoscopy
714
The colon, or large intestine, is the final segment of the digestive system. Its primary functions include absorbing water and vitamins produced by gut bacteria and transforming waste from liquid to solid to form stool. In adults, the large intestine is approximately 5 feet long and consists of four main sections:
714
Properties of Transition Metals
29.7K
Transition metals are defined as those elements that have partially filled d orbitals. As shown in Figure 1, the d-block elements in groups 3–12 are transition elements. The f-block elements, also called inner transition metals (the lanthanides and actinides), also meet this criterion because the d orbital is partially occupied before the f orbitals.
29.7K
Phase Transitions: Sublimation and Deposition
20.0K
Some solids can transition directly into the gaseous state, bypassing the liquid state, via a process known as sublimation. At room temperature and standard pressure, a piece of dry ice (solid CO2) sublimes, appearing to gradually disappear without ever forming any liquid. Snow and ice sublimate at temperatures below the melting point of water, a slow process that may be accelerated by winds and the reduced atmospheric pressures at high altitudes. When solid iodine is warmed, the solid sublimes...
20.0K
Detection of Gross Error: The Q Test
7.0K
When one or more data points appear far from the rest of the data, there is a need to determine whether they are outliers and whether they should be eliminated from the data set to ensure an accurate representation of the measured value. In many cases, outliers arise from gross errors (or human errors) and do not accurately reflect the underlying phenomenon. In some cases, however, these apparent outliers reflect true phenomenological differences. In these cases, we can use statistical methods...
7.0K


