五轴精密配送机的设计和基于视觉的校准
Ruizhou Wang1, Jinyu Liao1, Binghao Wang1
1State Key Laboratory of Precision Electronic Manufacturing Technology and Equipment, Guangdong University of Technology, Guangzhou 510006, China.
Micromachines
|January 28, 2026
概括
本研究引入了一种基于视觉测量 (VBM) 系统,用于识别五轴精密配剂机的几何误差. 该系统可实现自动校准,提高半导体包装的准确性.
科学领域:
- 机械工程 机械工程
- 机器人技术 机器人技术 机器人技术
- 计量学 计量学 计量学
背景情况:
- 五轴精密配剂机对于半导体包装至关重要.
- 这些机器中的几何错误显著影响了配剂的准确性.
- 现有的校准方法可能是复杂和耗时的.
研究的目的:
- 提出基于视觉测量 (VBM) 系统,用于识别和校准五轴配剂机的几何误差.
- 开发用于动力学校准和工件检测的自动化解决方案.
- 提高半导体包装工艺的整体准确性和可靠性.
主要方法:
- 建立了一个动力学模型,使用螺丝理论的指数乘积公式.
- 设计了一个几何错误识别算法,包括位置独立的几何错误 (PIGEs) 和位置依赖的几何错误 (PDGEs).
- 采用单数值分解和规则化来解决过度确定方程,并在A和C轴上识别PIGEs.
主要成果:
- 在A和C轴上,VBM系统成功识别了8个PIGE.
- 测量的平均空间位置误差为59.9微米,平均方向误差为160弧秒.
- 通过全面的错误测量验证了拟议的方法.
结论:
- VBM系统为五轴精密配送机提供了可行和自动化的校准解决方案.
- 开发的方法有效量化了几何误差,这对于高精度应用至关重要.
- 这种方法有助于提高半导体包装的精度.
相关概念视频
Hypothalamic-Pituitary Axis
65.9K
The response to stress—be it physical or psychological, acute or chronic—involves activation of the Hypothalamic-Pituitary-Adrenal (HPA) axis. The HPA axis is part of the neuroendocrine system because it involves both neuronal and hormonal communication. Its function is to regulate homeostatic systems—metabolic, cardiovascular, and immune—providing the necessary means to respond to a stressor.
65.9K
Vision
60.0K
Vision is the result of light being detected and transduced into neural signals by the retina of the eye. This information is then further analyzed and interpreted by the brain. First, light enters the front of the eye and is focused by the cornea and lens onto the retina—a thin sheet of neural tissue lining the back of the eye. Because of refraction through the convex lens of the eye, images are projected onto the retina upside-down and reversed.
60.0K
Glassware Calibration
1.4K
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
1.4K
Uncertainty in Measurement: Accuracy and Precision
100.9K
Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value.
100.9K
Instrument Calibration
732
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
732
Color Vision
1.5K
Color perception begins in the retina, the light-sensitive layer at the back of the eye. Two main theories explain how colors are seen: the trichromatic theory and the opponent-process theory. The trichromatic theory, proposed by Thomas Young in 1802 and extended by Hermann von Helmholtz in 1852, suggests that color vision is based on three types of cone receptors in the retina. These cones are sensitive to different but overlapping ranges of wavelengths corresponding to red, blue, and green.
1.5K