胎儿身体MRI成像中的3D稳定状态自由前行:一个有用的辅助序列
Kantheera Leesmidt1, Amanda Liu2, Liina Poder3
1Department of Radiology, Faculty of Medicine, Naresuan University, Phitsanulok, Thailand.
Acta radiologica open
|January 28, 2026
概括
胎儿磁共振成像 (MRI) 提供了一个非侵入性的方法来评估胎儿异常,当超声波是不确定的. 本综述强调了3D-FIESTA MRI在3T的使用,用于详细评估胎儿异常.
科学领域:
- 医疗成像医学成像
- 放射学 放射学是一门学科.
- 胎儿医学 胎儿医学
背景情况:
- 产前超声波是检测胎儿异常的标准.
- 超声波在排除或检测某些胎儿异常方面存在局限性.
- 胎儿MRI作为超声波的宝贵的非侵入性辅助.
研究的目的:
- 审查3D-FIESTA MRI在3T的实用性,用于评估胎儿异常.
- 展示如何从3D-FIESTA MRI中生成临床有用的信息.
- 用此技术评估的各种临床实体的图片概述.
主要方法:
- 使用三维快速成像采用稳定状态采集 (3D-FIESTA) 序列.
- 进行胎儿MRI检查,特别是在3特斯拉 (3T) 场强度.
- 采用图形复习格式来说明研究结果.
主要成果:
- 3D-FIESTA在3T提供了一系列胎儿异常的宝贵诊断信息.
- 这种技术在超声波检测结果不明确时尤为有用.
- 介绍了特定的临床实体及其MRI外观.
结论:
- 3D-FIESTA MRI在3T是一个有效的非侵入性工具,用于胎儿异常的评估.
- 这种成像模式增强了产前诊断和管理规划.
- 放射科医生可以利用3D-FIESTA MRI进行全面的胎儿评估.
关键词:
三维稳定状态自由前行3D稳定状态3D-FIESTA 3D-FIESTA 3D-FIESTA 3D-FIESTA 3D-FIESTA 3D-FIESTA 3D-FIESTA 3D-FIESTA 3D-FIESTA 3D-FIESTA 3D-FIESTA 3D-FIESTA 3D-FIESTA 3D-FIESTA 3D-FIESTA 3D-FIESTA 3D-FIESTA 3D-FIESTA 3D-FIESTA 3D-FIESTA 3D-FIESTA 3D-FIESTA 3D-FIESTA 3D胎儿核磁共振成像 (MRI) 的使用.胎儿的胎儿是一个胎儿.儿科 儿科 儿科 儿科产前诊断 产前诊断 产前诊断标题内容 标题内容 标题内容话题 话题 话题 话题相关概念视频
Gyroscope: Precession
5.4K
Precession can be demonstrated effectively through a spinning top. If a spinning top is placed on a flat surface near the surface of the Earth at a vertical angle and is not spinning, it will fall over due to the force of gravity producing a torque acting on its center of mass. However, if the top is spinning on its axis, it precesses about the vertical direction, rather than topple over due to this torque. Precessional motion is a combination of a steady circular motion of the axis and the...
5.4K
Steady State Concentration
5.9K
A steady state refers to the level of a drug in the body once it has reached an equilibrium between administration and elimination. It represents the point at which the drug administration rate equals the drug elimination rate, resulting in a relatively constant concentration in the body over time. The dynamic equilibrium is crucial to ensure the drug's effectiveness with minimal risk of toxicity.
Most drugs are administered in repeated doses at fixed intervals or through continuous...
Most drugs are administered in repeated doses at fixed intervals or through continuous...
5.9K
Heart Failure VI: Adjunct Therapies
314
Additional therapies for treating patients with heart failure (HF) may include procedural interventions, supplemental oxygen, the management of sleep disorders, and nutritional therapy.Procedural InterventionsImplantable Cardioverter-Defibrillator: For patients at risk of life-threatening arrhythmias due to severe left ventricular dysfunction, an Implantable Cardioverter-Defibrillator (ICD) can detect and terminate these arrhythmias, preventing sudden cardiac death and improving survival rates.
314
Atomic Nuclei: Larmor Precession Frequency
2.9K
The earth's gravitational field produces a 'twisting force' perpendicular to the angular momentum of a spinning mass (such as a spinning top) that causes the mass to 'wobble' around the gravitational field axis in a phenomenon called precession. Similarly, the magnetic moment (μ) of a spinning nucleus precesses due to an external magnetic field directed along the z-axis. The precession of the magnetic moment vector about the magnetic field is called Larmor precession,...
2.9K
Steady Flow of a Fluid Stream
745
Consider a control volume, such as a pipe with solid boundaries, through which fluid flows and changes direction due to the impulse exerted by the resulting force from the pipe walls. In steady flow, the mass of fluid entering the control volume at a given time, t, with velocity v1, is equal to the mass leaving after infinitesimal time dt, with velocity v2.
During this process, the momentum of the fluid within the control volume remains constant over the time interval dt. By applying the...
During this process, the momentum of the fluid within the control volume remains constant over the time interval dt. By applying the...
745
Transient and Steady-state Response
559
In control systems, test signals are essential for evaluating performance under various conditions. The ramp function is effective for systems undergoing gradual changes, while the step function is suitable for assessing systems facing sudden disturbances. For systems subjected to shock inputs, the impulse function is the most appropriate test signal.
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...
559