相关实验视频
Updated: Jan 30, 2026

07:22
Basophil Activation Test for Allergy Diagnosis
Published on: May 31, 2021
9.5K
环境驱动的免疫印记可以防止过敏
S Erickson1, B Lauring1, J Cullen1
1Department of Immunobiology, Yale University School of Medicine, New Haven, CT, USA.
Nature
|January 28, 2026
概括
接触免疫刺激环境会产生适应性免疫记忆,预防和抑制过敏性疾病. 这种交叉反应性免疫能提供对过敏原的保护,即使其序列相似性很低.
科学领域:
- 免疫学 免疫学 免疫学
- 环境健康 环境健康
- 过敏研究 研究过敏
背景情况:
- 过敏性疾病源于对环境触发物的 II 型过度免疫反应.
- 增加过敏患病率表明环境因素,而不是遗传因素是关键因素.
- 环境中介过敏保护的机制尚不清楚.
研究的目的:
- 研究环境暴露如何影响过敏疾病的发展.
- 阐明环境介导过敏保护背后的生物机制.
主要方法:
- 利用过敏疾病的小鼠模型.
- 研究了交叉反应适应性免疫记忆的作用.
- 评估了免疫刺激环境对II型免疫反应的影响.
主要成果:
- 暴露在免疫刺激环境中诱导了交叉反应适应性免疫记忆.
- 这种记忆阻碍了对过敏原暴露的II型免疫反应.
- 交叉反应性免疫保护了新的过敏敏感性,并抑制了现有的过敏.
结论:
- 证明了环境暴露与过敏预防/抑制之间的机制联系.
- 交叉反应,即使在一个宽容的背景下,防止过敏.
- 这些发现对理解自然环境中的适应性免疫有着广泛的影响.
相关概念视频
Imprinting
11.1K
Behavioral imprinting is observed in some newborn animals and occurs when they develop strong and specific attachments to another animal (usually a parent) following brief, early-life exposures. Offspring imprint onto parents within a brief period after birth or hatching; this time window is called the critical period. Once imprinting occurs, the bond established between the parents and their offspring is usually long-lasting.
11.1K
Genomic Imprinting and Inheritance
37.2K
Diploid organisms inherit genetic material through chromosomes from both parents. Copies of the same gene are known as alleles. In most cases, both alleles are simultaneously expressed and allow various cellular processes to function optimally. If one of the alleles is missing or mutated, the expression of the other allele can compensate; however, this is not true for all genes.
The expression of some genes depends on which parent passed the gene to the offspring, through a phenomenon known as...
The expression of some genes depends on which parent passed the gene to the offspring, through a phenomenon known as...
37.2K
What is the Immune System?
127.7K
Overview
127.7K
Protection of Alcohols
8.1K
This lesson delves into the concept of protection and deprotection of a functional group fundamental to synthetic organic chemistry. These phenomena are explained in the context of aliphatic and aromatic alcohols.
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
8.1K
Zones of Protection
793
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
793
Radial System Protection
439
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
439

