癌症患者中部脑膜动脉栓塞使用线圈治疗腹腔内血瘤:安全性和有效性
Taylor Hoffman1, Rozan Bokhari2, Isabelle Echelman3
1Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY 10065, USA; Baylor College of Medicine, School of Medicine, One Baylor Plaza, Houston, TX 77004, USA.
Journal of vascular and interventional radiology : JVIR
|January 30, 2026
概括
中间脑膜动脉 (MMA) 的单线栓塞是一种安全有效的治疗方法,用于癌症患者的腹膜下血瘤 (SDH). 在MMA栓塞后降低了血液瘤厚度,与该人群的生存率改善相关.
科学领域:
- 神经外科 神经外科
- 干预性放射学 干预性放射学
- 在瘤学瘤学.
背景情况:
- 脑下血液瘤 (SDH) 是癌症患者的一个重要并发症.
- 在这个人群中,SDH的治疗选择有限.
- 中脑膜动脉栓塞 (MMAE) 是一种新兴的SDH治疗方法.
研究的目的:
- 对癌症患者的SDH仅用线圈MMA栓塞的安全性和有效性进行评估.
- 评估MMAE后的临床和放射性结果.
- 为了确定SDH减少对整体存活率的影响.
主要方法:
- 对30名SDH癌症患者进行了回顾性分析,这些癌症患者接受了单线MMAE治疗.
- 评估血液瘤解脱,厚度变化,重新手术率和整体存活率.
- 统计分析包括威尔科克森签名等级测试和日志等级测试.
主要成果:
- 中位数SDH厚度在MMAE后显著下降 (12毫米至3.6毫米,p<0.001).
- 56%的患者显示SDH厚度减少了50%以上; 37%的患者实现了完全解脱.
- 降低血瘤厚度与显著更长的中位生存时间有关 (148 vs 29天,p = 0.0002).
结论:
- 单纯的MMAE是癌症患者SDH的安全有效治疗方法.
- 在MMAE之后,SDH厚度的减少与更好的生存率有关.
- 需要进一步的研究来探索高风险患者群体中的MMAE.
相关概念视频
Cranial and Spinal Meninges
4.0K
The cranial and spinal meninges are complex protective structures surrounding the central nervous system (CNS), consisting of the brain and spinal cord. These meninges consist of the dura mater, the arachnoid mater, and the pia mater. They protect the CNS, provide structural support, and aid in circulating cerebrospinal fluid (CSF).
Cranial Meninges
These meningeal layers cover the cranium. The dura mater is the outermost layer of cranial meninges. It is a thick and durable membrane of dense...
Cranial Meninges
These meningeal layers cover the cranium. The dura mater is the outermost layer of cranial meninges. It is a thick and durable membrane of dense...
4.0K
Pharmacodynamics in Geriatric Patients: Effects of Age
236
Age-related pharmacokinetic changes are extensively documented, but understanding age-related pharmacodynamic alterations is relatively limited. This knowledge gap can be partly attributed to the complexity of developing appropriate measures of drug responses compared to bioanalytical methods for determining drug concentrations.Most information regarding age-related differences in human pharmacodynamics originates from cross-sectional studies. However, these studies assume that observed mean...
236
Pulmonary Embolism I: Introduction
702
Pulmonary embolism (PE) occurs when a thrombus, fat or air embolus, amniotic fluid, or tumor tissue blocks one or more pulmonary arteries. These blockages originate in the venous system or the right side of the heart.EtiologyPE primarily arises from deep vein thrombosis (DVT) and other hypercoagulable states, such as inherited thrombophilias. Additional etiological factors include venous stasis, commonly seen in obesity, and endothelial injury from surgery and trauma. Less common causes include...
702
Survey Safety
394
Surveying near highways, rough terrain, or power lines involves significant risks. Working along highways is particularly dangerous and requires the use of warning signs and flagmen. It is safest to avoid working directly on roads and use offsets whenever possible. When highway work is unavoidable, it must follow all safety guidelines. Surveyors should wear bright clothing, such as orange reflective vests, to ensure visibility to motorists, coworkers, and hunters. In construction zones, wearing...
394
Buffer Effectiveness
55.2K
Buffer solutions do not have an unlimited capacity to keep the pH relatively constant . Instead, the ability of a buffer solution to resist changes in pH relies on the presence of appreciable amounts of its conjugate weak acid-base pair. When enough strong acid or base is added to substantially lower the concentration of either member of the buffer pair, the buffering action within the solution is compromised.
The buffer capacity is the amount of acid or base that can be added to a given volume...
The buffer capacity is the amount of acid or base that can be added to a given volume...
55.2K
Household Wiring And Electrical Safety
1.7K
Companies that supply power to most modern households use three conductors, typically called a three-wire line. While one is neutral, the other two are both at 120 V but with opposite polarity, giving a voltage of 240 V between them. With a three-wire line, high-power appliances that require 240 V, such as electric stoves and clothes dryers, are linked between the two hot lines. 120 V appliances can be connected between the neutral and either of the hot lines. The neutral side, which is always...
1.7K


