相关实验视频
Updated: Feb 2, 2026

16:11
Implantation of the Syncardia Total Artificial Heart
Published on: July 18, 2014
36.0K
在双边肺切除术后,使用流量适应性体外全人工肺系统进行移植的桥梁
Yuanqing Yan1, Anitha Chandrasekhar1, Hee Chul Yang1
1Division of Thoracic Surgery, Canning Thoracic Institute, Northwestern University Feinberg School of Medicine, 676 N. Saint Clair Street Ste. 650, Chicago, IL 60656, USA.
Med (New York, N.Y.)
|January 31, 2026
概括
一种新型的体外全人工肺 (TAL) 系统使两侧肺切除术可用于严重的肺炎,使患者能够过渡到肺移植. 这种创新方法为患有耐火性败血症的重症患者提供了潜在的救援策略.
科学领域:
- 心血管和呼吸系统生理学 心血管和呼吸系统生理学
- 移植医学 移植医学
- 关键护理医学 关键护理医学
背景情况:
- 严重的急性呼吸困扰综合征 (ARDS) 伴随死性肺炎和败血性休克的死亡率很高.
- 由于持续性败血症,不确定的损伤可逆性和血液动力学不稳定性,肺部移植往往是不可行的.
研究的目的:
- 开发和评估一种体外全人工肺 (TAL) 系统,用于ARDS,死性肺炎和耐火性败血性休克患者的双边肺切除术.
- 评估使用TAL系统作为桥梁到肺移植的可行性.
主要方法:
- 开发一种外体TAL系统,配有流量适应的分流器和双左心房回归管道.
- 双边肺切除术用于ARDS和耐火性败血症休克患者的源控制.
- 扩充肺部的单细胞和空间转录基因分析,以分析细胞和分子变化.
主要成果:
- 该TAL系统支持肺切除术后的患者,解决了血管压缩剂的需求.
- 转录组分析显示扩散的肺部破坏,炎症细胞透和异常细胞扩张,表明不可逆转的损伤.
- 患者在成功进行肺移植两年后实现了优异的心肺功能.
结论:
- 外体TAL系统可以促进安全的双边肺切除术,以控制不移植性肺炎的患者的源控制.
- 这种方法可以作为一个可行的救援策略,将选定的患者连接到成功的肺移植.
相关概念视频
Design Example: Strain Gauge Bridge or Wheatstone Bridge
1.0K
The utilization of strain gauges as transducers for converting mechanical strain into electrical signals is a common practice in various engineering applications. These strain gauges are frequently integrated into Wheatstone bridge circuits to accurately measure parameters such as force or pressure. Within this context, each element within the circuit exhibits a resistance that undergoes subtle variations when subjected to mechanical strain. The primary objective is to convert minuscule...
1.0K
Wheatstone Bridge
1.2K
An ohmmeter is a resistance-measuring device. It works by applying a voltage to a resistor of unknown resistance and measuring the current across the resistor. The resistance value is deduced using Ohm's law. Usually, the standard configuration of an ohmmeter comprises a voltmeter or an ammeter. However, such configurations are limited in accuracy because the meters alter the voltage applied to the resistor and the current that flows through it.
Thus, for accurate resistance measurements, a...
Thus, for accurate resistance measurements, a...
1.2K
Bridge rectifier
1.6K
The bridge rectifier is essential in electronics for efficiently converting alternating current (AC) to direct current (DC). Comprised of four diodes configured in a bridge layout, this rectifier effectively processes both the positive and negative halves of the AC waveform, making it superior to half-wave and full-wave center-tapped rectifiers in terms of voltage regulation and output stability.
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
1.6K
Cross-bridge Cycle
122.7K
As muscle contracts, the overlap between the thin and thick filaments increases, decreasing the length of the sarcomere—the contractile unit of the muscle—using energy in the form of ATP. At the molecular level, this is a cyclic, multistep process that involves binding and hydrolysis of ATP, and movement of actin by myosin.
122.7K
Lung Capacity
56.3K
The air in the lungs is measured in volumes and capacities. Lung volume measures reflect the amount of air taken in, released, or left over after a lung function, like a single inhalation. Lung capacity measures are sums of two or more lung volume measures.
56.3K
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
226
Hemoperfusion and hemofiltration are critical techniques in medical treatments to eliminate accumulated drugs, metabolites, and electrolytes from the bloodstream. These methods are particularly vital in cases of accidental poisoning and drug overdose.Hemoperfusion involves passing blood through an adsorbent material to remove unwanted substances. The main adsorbents used in hemoperfusion include activated charcoal and Amberlite resins. Activated charcoal can adsorb both polar and nonpolar...
226

