Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Flow Cytometry01:23

Flow Cytometry

16.2K
The development of flow cytometry techniques began in 1934 with initial attempts by Andrew Moldavan, a bacteriologist who counted the cells in a flowing capillary system. Moldavan pumped cells through a capillary tube focused under a microscope for visualization. The invention of photometry allowed the measurement of differentially-stained cells, and Louis Kamentsky developed the first multiparameter flow cytometer in 1965 to identify and count the cancer cells in cervical tissue specimens.
In...
16.2K
Wave Parameters01:10

Wave Parameters

9.4K
The simplest mechanical waves are associated with simple harmonic motion and repeat themselves for several cycles. These simple harmonic waves can be modeled using a combination of sine and cosine functions. Consider a simplified surface water wave that moves across the water's surface. Unlike complex ocean waves, in surface water waves, water moves vertically, oscillating up and down, whereas the disturbance of the wave moves horizontally through the medium. If a seagull is floating on the...
9.4K
Distributions to Estimate Population Parameter01:26

Distributions to Estimate Population Parameter

5.1K
The accurate values of population parameters such as population proportion, population mean, and population standard deviation (or variance) are usually unknown. These are fixed values that can only be estimated from the data collected from the samples. The estimates of each of these parameters are sample proportion, the sample mean, and sample standard deviation (or variance). To obtain the values of these sample statistics, data are required that have particular distribution and central...
5.1K
Noncompartmental Analysis: Miscellaneous Pharmacokinetic Parameters00:54

Noncompartmental Analysis: Miscellaneous Pharmacokinetic Parameters

453
The noncompartmental approach is a widely used method in pharmacokinetics to assess drugs' behaviors in the body. It considers several factors, including clearance, bioavailability, and total volume of distribution.
One key aspect of the noncompartmental approach is determining a drug's total clearance. This can be done by dividing the drug dose by the area under the concentration-time curve from zero to infinity. The area under the concentration-time curve represents the drug's...
453
Dosage Regimens: Partial Pharmacokinetic Parameters01:01

Dosage Regimens: Partial Pharmacokinetic Parameters

175
It is not uncommon for complete drug pharmacokinetic profiles to remain elusive in pharmacokinetics. This necessitates certain educated assumptions by pharmacokineticists to determine appropriate dosage regimens without comprehensive pharmacokinetic data from animal or human studies. One prevalent assumption is setting the bioavailability factor, denoted as F, to 1 or 100%. This assumption caters to the scenario where a drug doesn't achieve full systemic absorption, resulting in the patient...
175
Gene Flow02:39

Gene Flow

37.8K
Gene flow is the transfer of genes among populations, resulting from either the dispersal of gametes or from the migration of individuals.
37.8K

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Epcoritamab plus rituximab, dexamethasone, cytarabine, oxaliplatin/carboplatin induces deep and durable responses in transplant-eligible patients with relapsed or refractory diffuse large B-cell lymphoma: results from the EPCORE NHL-2 trial.

Haematologica·2026
Same author

Measuring T-cell/CAR T-cell bystander tumor killing in vitro and in vivo.

Methods in cell biology·2026
Same author

Quantification and functional assessment of antigen(-) tumor cell variants.

Methods in cell biology·2026
Same author

Mouse and human T cell Cas9-RNP/nucleofection-mediated gene-editing.

Methods in cell biology·2026
Same author

Armored macrophage-targeted CAR-T cells reset and reprogram the tumor microenvironment and control metastatic cancer growth.

Cancer cell·2026
Same author

Nivolumab plus brentuximab vedotin for relapsed/refractory diffuse large B-cell lymphoma.

Future oncology (London, England)·2025

相关实验视频

Updated: Feb 2, 2026

Analysis of Cell Suspensions Isolated from Solid Tissues by Spectral Flow Cytometry
11:08

Analysis of Cell Suspensions Isolated from Solid Tissues by Spectral Flow Cytometry

Published on: May 5, 2017

13.5K

高参数T细胞光谱光流细胞计.

Gvantsa Pantsulaia1, Joshua Brody1

  • 1Division of Hematology and Medical Oncology, Department of Medicine, Icahn School of Medicine at Mount Sinai, New York, NY, United States; Precision Immunology Institute, Icahn School of Medicine at Mount Sinai, New York, NY, United States; Tisch Cancer Institute, Icahn School of Medicine at Mount Sinai, New York, NY, United States.

Methods in cell biology
|January 31, 2026
PubMed
概括

光流细胞计,结合光细胞条形码,提供了强大的免疫信号分析. 这项研究提出了一种标准化的方法来刺激T细胞,提高实验的可重复性和减少流细胞计试验的变异性.

关键词:
癌症免疫疗法癌症免疫疗法细胞信号传递 细胞信号传递光细胞条形码编码免疫细胞简介.体流动细胞计量法 体流动细胞计信号传导传导是指信号的传导.激活T细胞的激活过程

更多相关视频

Phospho Flow Cytometry with Fluorescent Cell Barcoding for Single Cell Signaling Analysis and Biomarker Discovery
08:38

Phospho Flow Cytometry with Fluorescent Cell Barcoding for Single Cell Signaling Analysis and Biomarker Discovery

Published on: October 4, 2018

21.8K
Flow Cytometry Purification of Mouse Meiotic Cells
10:43

Flow Cytometry Purification of Mouse Meiotic Cells

Published on: April 15, 2011

18.3K

相关实验视频

Last Updated: Feb 2, 2026

Analysis of Cell Suspensions Isolated from Solid Tissues by Spectral Flow Cytometry
11:08

Analysis of Cell Suspensions Isolated from Solid Tissues by Spectral Flow Cytometry

Published on: May 5, 2017

13.5K
Phospho Flow Cytometry with Fluorescent Cell Barcoding for Single Cell Signaling Analysis and Biomarker Discovery
08:38

Phospho Flow Cytometry with Fluorescent Cell Barcoding for Single Cell Signaling Analysis and Biomarker Discovery

Published on: October 4, 2018

21.8K
Flow Cytometry Purification of Mouse Meiotic Cells
10:43

Flow Cytometry Purification of Mouse Meiotic Cells

Published on: April 15, 2011

18.3K

科学领域:

  • 免疫学 免疫学 免疫学
  • 细胞信号传输 细胞信号传输
  • 流动细胞计量 (Flow Cytometry) 是一种流动细胞计.

背景情况:

  • 光流细胞计对于研究免疫信号来说至关重要,它可以同时检测细胞标记物和细胞内光蛋白.
  • 它在诊断,治疗,药物查和疗效评估方面具有潜在的应用.
  • 光细胞条形编码 (FCB) 提高了流动细胞计量吞吐量和实验的稳定性.

研究的目的:

  • 描述一种标准化的实验方法来刺激小鼠和人类的T细胞.
  • 在光流量测试中解决操作者间的变异性.
  • 为强大的T细胞激活提供一个可适应的协议.

主要方法:

  • 开发一个标准化的T细胞刺激协议.
  • 光流与光细胞条形码 (FCB) 集成用于复杂化.
  • 适用于小鼠和人类T细胞激活研究.

主要成果:

  • 使用描述的方法证明强大的T细胞激活.
  • 改善了实验一致性,减少了流式细胞计染色的变异性.
  • 成功适应各种实验设计.

结论:

  • 这种方法提供了一个标准化的T细胞刺激方法,用于光流分析.
  • 这种标准化提高了可重现性,并减少了免疫信号研究中的变异性.
  • 这种可适应的协议支持高通量流细胞计应用.