一项国际前性,非随机的比较研究,在良性附带性妇科外科手术中使用发光镜仪表进行表达
Young Eun Chung1, Seongyun Lim1, Jun-Hyeong Seo1
1Gynecologic Cancer Center, Department of Obstetrics and Gynecology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.
概括
关节性腹腔镜仪器 (Artisential®) 在良性附手术中是可行的和安全的. 这项研究发现,与传统腹腔镜工具相比,结果没有显著差异.
科学领域:
- 最少侵入性的妇科手术
- 手术技术创新 手术技术创新
背景情况:
- 关节性腹腔镜仪器提供了增强的灵巧性,但缺乏良性妇科手术的广泛证据.
- 关于Artisential®仪器在这个外科领域的术后安全性和可行性的数据有限.
研究的目的:
- 评估Artisential®关节仪器的可行性和外科安全性.
- 为了比较Artisential®在良性附带外科手术中的使用与传统腹腔镜仪器的结果.
主要方法:
- 多中心,前性,非随机比较研究与倾向性得分匹配.
- 连续接受了为良性附带性疾病进行腹腔镜手术的患者被纳入.
- 结果包括手术时间,血液损失,住院时间和并发症 (Clavien-Dindo分级).
主要成果:
- 分析了184名患者,包括112名匹配对.
- 在操作结果中,Artisential®与传统仪器之间没有显著差异.
- 没有手术转换或输血;并发症是罕见的和轻微的 (I级港口网站问题).
结论:
- Artisential®关节仪表在腹腔镜良性附带手术中证明了可行性和短期安全性.
- 建议进一步进行随机对照试验,以评估长期的人体工程学和经济优势.
相关概念视频
Articulations of the Vertebral Column
3.1K
In addition to being held together by the intervertebral discs, adjacent vertebrae also articulate with each other at synovial joints formed between the superior and inferior articular processes called zygapophysial joints (facet joints). These are plane joints that provide for only limited motions between the vertebrae. The orientation of the articular processes at these joints varies in different regions of the vertebral column and serves to determine the types of motions available in each...
3.1K
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
248
Body:Bioequivalence experimental study designs are crucial methodologies used in evaluating and comparing the bioavailability of different drug products. These designs are categorized into various types: completely randomized, randomized block, repeated measures, cross and carry-over, and Latin square designs.Completely randomized designs involve randomly allocating treatments to all subjects participating in the experiment. This allocation is achieved by assigning unique random numbers to...
248
Internal Energy
36.8K
The total of all possible kinds of energy present in a substance is called the internal energy (U), sometimes symbolized as E. Suppose a system with initial internal energy, Uinitial, undergoes a change in energy (transfer of work or heat), and the final internal energy of the system is Ufinal. Change in internal energy equals the difference between Ufinal and Uinitial.
36.8K
Internal Receptors
74.7K
Many cellular signals are hydrophilic and therefore cannot pass through the plasma membrane. However, small or hydrophobic signaling molecules can cross the hydrophobic core of the plasma membrane and bind to internal, or intracellular, receptors that reside within the cell. Many mammalian steroid hormones use this mechanism of cell signaling, as does nitric oxide (NO) gas.
74.7K
Instrument Calibration
752
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
752
Instrumentation Amplifier
1.1K
An electrocardiography (ECG) machine is an essential piece of medical equipment used to monitor the electrical activity of the heart. It operates by detecting small electrical changes on the skin that result from the depolarization of the heart muscle during each heartbeat. However, these signals are in the microvolt range and can be easily overwhelmed by noise or interference.
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
1.1K