低损耗SAW RFID使用反射式多条带合器作为反射器
Junhao Cao1, Tianyi He1, Guangzu Zhang1
1School of Integrated Circuits, Huazhong University of Science and Technology, Wuhan, 430074, China.
Microsystems & nanoengineering
|February 2, 2026
概括
这项研究引入了一种新的表面声波无线电频率识别 (SAW RFID) 设计,使用反射式多条纹合器 (RMSC). 这一创新通过改善SAW RFID系统的信号反射来显著提高无线查询范围.
科学领域:
- 物理 物理学 物理
- 电气工程 电气工程
- 材料科学 材料科学 材料科学
背景情况:
- 表面声波无线电频率识别 (SAW RFID) 对于遥感和识别至关重要.
- 传统的SAW RFID标签在无线查询范围内面临限制,原因是低反射率反射器的能量损耗.
研究的目的:
- 提出并验证使用反射式多条纹合器 (RMSC) 的新型SAW RFID架构.
- 为了克服传统反射器的局限性,并增强SAW RFID系统的无线查询范围.
主要方法:
- 采用RMSC,利用波形模式之间的速度差异进行连贯反射.
- 进行数值模拟以分析性能和优化条形数量.
- 在128°YX-LiNbO3基板上制造并测试了一种433 MHz SAW RFID原型.
主要成果:
- 与模拟相比,实现了1dB的低损失和最小的反射率差异 (0.33dB).
- 显示了 -10.63 dB的峰值时域振幅,比传统设计显著改进.
- 在广泛的温度范围 (-20°C至90°C) 中确认了线性时间延迟和相位响应,R2 > 0.9999.
结论:
- RMSC反射器是一种高反射率解决方案,用于提高SAW RFID性能.
- 这项技术为推进远程无线传感应用提供了巨大的潜力.
相关概念视频
Line Loss
543
The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
543
Reflection of Waves
4.6K
When a wave travels from one medium to another, it gets reflected at the boundary of the second medium. A common example of this is when a person yells at a distance from a cliff and hears the echo of their voice. The sound waves (longitudinal waves) traveling in the air are reflected from the bounding cliff. Similarly, flipping one end of a string whose other end is tied to a wall causes a pulse (transverse wave) to travel through the string, which gets reflected upon reaching the wall. In...
4.6K
Reducing Line Loss
390
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
390
The Sense of Self: Reflected Self-Appraisal and Social Comparison
56.1K
According to Charles Cooley, we base our image on what we think other people see (Cooley 1902). We imagine how we must appear to others, then react to this speculation. We don certain clothes, prepare our hair in a particular manner, wear makeup, use cologne, and the like—all with the notion that our presentation of ourselves is going to affect how others perceive us. We expect a certain reaction, and, if lucky, we get the one we desire and feel good about it. But more than that, Cooley...
56.1K
Energy Losses in Transformers
1.3K
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
1.3K
Major Losses in Pipes
2.0K
When a fluid flows through a pipe, it experiences energy losses due to frictional resistance along the pipe walls, known as major losses. These energy losses result in a pressure drop, which varies based on the flow conditions — whether laminar or turbulent — and the specific physical properties of the fluid and pipe.
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
2.0K


