引的困难和并发症-ICD引设计是否重要?
Andrzej Kutarski1, Wojciech Jacheć1, Paweł Stefańczyk2
12nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Katowice, Poland.
Pacing and clinical electrophysiology : PACE
|February 3, 2026
概括
植入式心脏转换器-除器 (ICD) 引线的静脉输血取 (TLE) 比起心脏起器 (PM) 引线更安全,更简单,并没有太多严重的并发症. 领先的设计没有显著影响TLE安全性,但一些制造商的成功率较低.
科学领域:
- 心脏病学 心脏病学
- 医疗器械 医疗器械
- 手术手术手术手术手术手术手术手术手术手术
背景情况:
- 植入式心脏转换器-除器 (ICD) 导线的静脉移除被认为是具有挑战性和高风险的.
- 了解ICD设计对输血提取 (TLE) 安全性和有效性的影响至关重要.
研究的目的:
- 调查ICD设计对跨静脉取 (TLE) 的安全性和有效性的影响.
- 为了比较ICD引线和心脏起器 (PM) 引线之间的TLE结果.
主要方法:
- 追溯分析了3929个TLE程序,其中包括1068个涉及ICD取.
- 在ICD和PM提取之间比较主要的并发症率,程序复杂性和成功率.
主要成果:
- 在提取时,ICD线索显著更年轻 (PM线索的中位数为61个月,而PM线索的中位数为97个月).
- 对于ICD提取 (0.75%) 与PM提取 (2.25%) 相比,主要并发症的发生率较低.
- 与ICD提取相比,PM提取的完整程序成功率较低.
结论:
- ICD取通常不那么复杂,而且比PM取更安全,可能是由于植入时间更短.
- 根据ICD主要制造商,没有观察到TLE复杂性或并发症的显著差异.
- 与Abbott和Biotronik的ICD线索相比,与Medtronic线索相比,完全程序成功率较低.
相关概念视频
Phase-lead and Phase-lag Controllers
550
Understanding the working function of different types of controllers can be illustrated with practical analogies, such as adjusting a stereo's volume equalizer. Cranking up the bass involves a phase-lead controller, which functions as a high-pass filter, while increasing the treble uses a phase-lag controller, which acts as a low-pass filter. PD controllers, similar to high-pass filters, enhance the system's response to high-frequency components. PI controllers, akin to low-pass...
550
Time and frequency -Domain Interpretation of Phase-lead Control
455
Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
455
Hemodialysis II: Procedure and Complications
844
DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
844
Group Design
10.5K
The most basic experimental design involves two groups: the experimental group and the control group. The two groups are designed to be the same except for one difference— experimental manipulation. The experimental group gets the experimental manipulation—that is, the treatment or variable being tested—and the control group does not. Since experimental manipulation is the only difference between the experimental and control groups, we can be sure that any differences between...
10.5K
Pneumonia III: Complications and Assessment
873
Pneumonia poses the potential for numerous complications that warrant consideration. These complications include the following:
873
Diabetes: Symptoms, Diagnosis, and Complications
2.3K
For most patients, experiencing several weeks of polyuria, polydipsia, fatigue, and significant weight loss may indicate the presence of diabetes. Furthermore, adults displaying the phenotypic appearance of type 2 diabetes (particularly those who are obese and not initially insulin-requiring), may have islet cell autoantibodies, suggesting autoimmune-mediated β cell destruction and a diagnosis of latent autoimmune diabetes of adults (LADA). The categorization of glucose homeostasis is...
2.3K