概括
在乳房重建时的植入前污染可能并不总是导致感染. 精心的手术后护理对于减少手术部位感染和改善患者结果至关重要.
科学领域:
- 手术部位感染 手术部位感染
- 进行乳房重建手术.
- 基于植入物的程序是基于植入物的程序.
背景情况:
- 手术部位感染 (SSI) 率在乳腺手术中为<1.5%,在基于植入物的重建中增加到3%.
- 调查植入前污染作为术后感染的来源至关重要.
研究的目的:
- 评估乳房重建中植入物插入前是否发生污染.
- 确定植入前污染和术后感染之间的关系.
主要方法:
- 在植入物插入之前,从周围的区域和暴露的外科边缘收集的抽样培养.
- 标准的手术现场准备用贝塔丁溶液和布.
- 在植入物插入之前,重新应用消毒剂和重新涂布.
- 对感染迹象进行2年的随访.
主要成果:
- 在164例中,有13例 (7.9%) 呈现出阳性植入前擦拭物培养 (主要是*Staphylococcus epidermidis*).
- 只有一个阳性培养的患者患上了手术后感染.
- 在151名阴性培养患者中,有10名患有术后感染,通常涉及黄金菌.
结论:
- 尽管进行了初始绝育,但残留污染可能仍然存在.
- 在植入物插入之前重新应用消毒剂和重新覆盖可能会减少SSI.
- 术后管理至关重要,因为有些感染可能不是来自植入前的污染.
相关概念视频
Cleaning, Sterilization, and Disinfection
10.3K
Cleaning, disinfection, and sterilization are the methods that help to break the infection chain and prevent disease.
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
10.3K
Methods of Sterilization II: Chemical Methods
9.1K
In healthcare, the chemical method of sterilization uses chemical sterilants to treat surgical instruments and medical supplies to help prevent the transmission of infectious pathogens to patients. Due to heat sensitivity, most medical supplies and equipment should not be exposed to high temperatures. These parts include rubber, plastic, glass, and other similar elements.
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
9.1K
Methods of Sterilization I: Physical Methods
23.6K
As used in a healthcare facility, sterilization destroys all microorganisms through physical or chemical methods. The physical method includes steam, dry heat, boiling water, and radiation.
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
23.6K
Reconstruction of Signal using Interpolation
734
Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next...
734
Porin Insertion in the Outer Mitochondrial Membrane
4.8K
Porins are beta-barrel proteins translocated to the mitochondrial outer membrane through the TOM complex into the intermembrane space. Porin precursors bind TIM chaperones within the intermembrane space and are guided to the Sorting and Assembly Machinery complex or SAM complex on the outer mitochondrial membrane.
Three models describe the assembly of porins by the SAM complex and their insertion into the outer membrane. Model 1 suggests that porins are assembled outside the SAM channel as the...
Three models describe the assembly of porins by the SAM complex and their insertion into the outer membrane. Model 1 suggests that porins are assembled outside the SAM channel as the...
4.8K
Insertion of Single-pass Transmembrane Proteins in the RER
18.1K
Integral membrane proteins are proteins adhered to the lipid bilayer of a cell organelle or membrane. They can be of two types: transmembrane integral proteins that span the lipid bilayer and monotopic proteins that are attached to either side of the membrane but do not pass through it.
Integral transmembrane proteins possess transmembrane and extra membrane domains. The transmembrane domains are primarily made of 20-25 hydrophobic amino acids arranged in a helical secondary confirmation. These...
Integral transmembrane proteins possess transmembrane and extra membrane domains. The transmembrane domains are primarily made of 20-25 hydrophobic amino acids arranged in a helical secondary confirmation. These...
18.1K