一个紧的Rn-220参考室,温度和湿度不变.
Hongbo Xu1, Zhongkai Fan1, Ruomei Xie1
1College of Physics and Electronic Engineering, Hengyang Normal University, Hengyang, Hunan Province, 421008, China.
概括
为辐射研究开发了一种新的紧型-220 (Rn-220) 参考室. 该系统提供稳定的温度和湿度,达到适合仪器校准的高Rn-220度.
科学领域:
- 环境科学 环境科学
- 核物理 核物理 核物理
- 计量学 计量学 计量学
背景情况:
- -220 (Rn-220) 是辐射研究中的关键放射性同位素.
- 辐射检测仪器的准确校准需要稳定的参考源.
- 对于某些应用,现有的Rn-220源可能缺乏稳定性或紧性.
研究的目的:
- 设计和开发一种新的,紧的Rn-220参考室.
- 确保室内环境条件 (温度和湿度) 稳定.
- 建立一个可靠的Rn-220源用于与辐射相关的实验研究和仪器校准.
主要方法:
- 一个200L不钢圆柱形室被建造.
- 用添加剂的灯被用作Rn-220放射性源.
- 使用超和盐溶液控制湿度,并从外部稳定温度.
- 使用风扇实现了空气混合,并使用RAD7探测器监测Rn-220度.
主要成果:
- 室内保持稳定的条件:相对湿度为73 ± 3%,温度为31 ± 1°C.
- 在36个地幔中,Rn-220度达到了166,700 ± 35,300 Bq m−3.
- 作为参考来源,选择的9层形配置产生了47,700 ± 12,400 Bq m−3,不确定性为26.0%,垂直变化最小.
结论:
- 成功开发了一个紧而稳定的Rn-220参考室.
- 该室提供受控的环境条件和高Rn-220度.
- 该设备适用于仪器校准和各种辐射研究应用.
关键词:
RAD7 RAD7 RAD7 RAD7 RAD7 RAD7 RAD7 RAD7 RAD7 RAD7 RAD7 RAD7 RAD7 RAD7 RAD7 RAD7稳定的温度和湿度 Rn-220室内标准化的实验环境.添加剂的灯斗.更多相关视频
07:44Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy
Published on: April 27, 2016
10.1K
05:56Construction of a Compact Low-Cost Radiation Shield for Air-Temperature Sensors in Ecological Field Studies
Published on: November 6, 2018
8.7K
相关概念视频
Compact Bone
16.6K
Most bones contain compact and spongy osseous tissue, but their distribution and concentration vary based on the bone's overall function.
Compact bone, also called cortical bone, is the denser, stronger of the two types of bone tissue. It is found under the periosteum and in the diaphyses of long bones, where it provides support and protection. The microscopic structural unit of compact bone is called an osteon, or haversian system. Each osteon is composed of concentric rings of calcified...
Compact bone, also called cortical bone, is the denser, stronger of the two types of bone tissue. It is found under the periosteum and in the diaphyses of long bones, where it provides support and protection. The microscopic structural unit of compact bone is called an osteon, or haversian system. Each osteon is composed of concentric rings of calcified...
16.6K
Compacting Factor test
597
The compacting factor test is a method used to assess the workability of concrete. It is especially suitable for concrete mixes containing aggregates up to one and a half inches in size. This test involves specialized equipment consisting of two truncated cone-shaped hoppers and a cylinder, all with polished interior surfaces to minimize friction.
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
597
Constant Pressure Calorimetry
97.7K
Calorimetry is a technique used to measure the amount of heat involved in a chemical or physical process or to measure the heat transferred to or from a substance. The heat is exchanged with a calibrated and insulated device called the calorimeter. Calorimetry experiments are based on the assumption that there is no heat exchange between the insulated calorimeter and the external environment. The well-insulated calorimeters prevent the transfer of heat between the calorimeter and its external...
97.7K
Constant Volume Calorimetry
30.8K
Calorimeters are useful to determine the heat released or absorbed by a chemical reaction. Coffee cup calorimeters are designed to operate at constant (atmospheric) pressure and are convenient to measure heat flow (or enthalpy change) accompanying processes that occur in solution at constant pressure. A different type of calorimeter that operates at constant volume, colloquially known as a bomb calorimeter, is used to measure the energy produced by reactions that yield large amounts of heat and...
30.8K
Calculating the Equilibrium Constant
38.1K
The equilibrium constant for a reaction is calculated from the equilibrium concentrations (or pressures) of its reactants and products. If these concentrations are known, the calculation simply involves their substitution into the Kc expression.
For example, gaseous nitrogen dioxide forms dinitrogen tetroxide according to this equation:
For example, gaseous nitrogen dioxide forms dinitrogen tetroxide according to this equation:
38.1K
Inertial Frames of Reference
8.8K
Newton’s first law is usually considered to be a statement about reference frames. It provides a method for identifying a special type of reference frame: the inertial reference frame. In principle, we can make the net force on a body zero. If its velocity relative to a given frame is constant, then that frame is said to be inertial. So, by definition, an inertial reference frame is a reference frame where Newton's first law holds valid. Newton's first law applies to objects with...
8.8K
