长期骨髓炎后的大片损失的支柱骨的化
Abraham G Negussie1, Metasebia W Abebe2, Tesfaye B Meles2
1From the Plastic and Reconstructive Surgery Unit, ALERT Hospital, Addis Ababa University, College of Health Science, Addis Ababa, Ethiopia.
Plastic and reconstructive surgery. Global open
|February 9, 2026
概括
双侧支柱骨化有效地重建感染后儿童的大支柱骨缺陷. 这种肢体救生技术恢复了10岁男孩患有严重骨损失的功能.
科学领域:
- 整形外科手术 整形外科手术
- 儿科整形医生 儿科整形医生
- 肢体的重建 肢体的重建
背景情况:
- 骨对于支体重至关重要,但其暴露的位置有感染和骨损失的风险.
- 大段性骨缺陷带来了显著的重建挑战,特别是在儿科患者中.
- 在这种情况下,之前的重建尝试没有成功.
研究的目的:
- 提出一个成功的四肢救生策略,用于广泛的小腿骨缺陷在儿科患者.
- 在一个复杂的儿科病例中,评价 ipsilateral 支柱状的疗效.
- 突出微手术重建的可行替代方案.
主要方法:
- 一个10岁男孩的病例报告,患有感染的骨缩和骨损失.
- 使用与外部固定器的ipsilateral 支柱状带的手术重建.
- 用达金溶液和物理治疗进行术后伤口护理.
主要成果:
- 通过外部固定器在6个月后成功实现了骨结合.
- 患者在14个月时恢复了短距离无助行走的行走能力.
- 剩余的膝盖和脚硬度通过持续的物理治疗来管理.
结论:
- 双侧带化是儿童大缺陷的一个可靠的肢体救生选择.
- 当微手术选择有限时,这种技术提供了一个可行的解决方案.
- 有效的感染管理和适当的固定是成功结果的关键.
相关概念视频
Bones of the Lower Limb: Tibia and Fibula
9.6K
The tibia is the main weight-bearing bone of the lower leg. It is larger than the fibula with which it is paired. The tibia is also the second longest bone in the body and is located right below the skin. The proximal end of the tibia forms the medial and the lateral condyle, which articulates with the condyles of the femur to form the knee joint. Between the articulating surfaces is the irregular elevated area known as the intercondylar eminence that serves as the inferior attachment point for...
9.6K
Line Loss
545
The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
545
Reducing Line Loss
392
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
392
Major Losses in Pipes
2.0K
When a fluid flows through a pipe, it experiences energy losses due to frictional resistance along the pipe walls, known as major losses. These energy losses result in a pressure drop, which varies based on the flow conditions — whether laminar or turbulent — and the specific physical properties of the fluid and pipe.
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
2.0K
Minor Losses in Pipes
2.0K
In pipe systems, minor losses refer to energy losses arising from components such as valves, bends, fittings, expansions, and other features that disrupt the steady flow of fluid. These disturbances cause energy dissipation through turbulence and resistance, which engineers quantify to manage system efficiency effectively.
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
2.0K
Energy Losses in Transformers
1.3K
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
1.3K


