在患有白内障和高近视的患者中使用Angle Kappa
Ao Miao1,2,3,4, Dongjin Qian1,2,3, Jiajia Huang1
1Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, 200030, China.
Ophthalmology and therapy
|February 9, 2026
概括
高近视 (轴长≥26mm) 和轴长≥30mm是大角度卡帕距离的危险因素. 在高近视眼中,角卡帕最常见于上象限.
科学领域:
- 眼科医生 眼科 眼科
- 视光学测量 视光学测量 视光学测量
- 生物医学光学 生物医学光学
背景情况:
- 视角卡帕,视觉和瞳孔轴之间的错位,在眼科评估中至关重要.
- 高近视 (轴长≥26毫米) 和与年龄相关的白内障是影响视觉功能的常见疾病.
- 了解高近视的角卡帕分布对于准确的光学校正和手术规划至关重要.
研究的目的:
- 为了研究白内障和高近视患者角卡帕的大小和象限分布.
- 在这个群体中确定与大角度卡帕距离 (≥0.5毫米) 相关的风险因素.
主要方法:
- 总共包括了2485名白内障和高近视患者和354名白内障但没有高近视患者.
- 使用Oculus Pentacam HR. 的角度卡帕位置和值被测量.
- 用多变量线性回归分析来确定相关因素.
主要成果:
- 较长的轴长度 (≥30毫米),较窄的白至白距离,较低的角质量测量,较高的角膜纹症和较长的年龄显着与高近视眼中的较大角卡帕距离有关.
- 确定了30mm的轴长为大角度卡帕距离的切割点 (AUC = 0.64).
- 在高近视眼中,最常见的角度卡帕位置是上部 (40%) 和下部 (26%). 在非高近视眼中,鼻上部 (31%) 和鼻下部 (31%) 是最常见的.
结论:
- 30毫米或更大的轴长为大角度卡帕距离的显著风险因素.
- 上象限是高近视眼中角卡帕的主要位置.
- 这些发现对高近视和白内障患者的折射手术和光学设备设计有意义.
相关概念视频
Contact Angle
22.5K
When a solid is dipped inside a liquid, the liquid surface becomes curved near the contact. For some solid–liquid interfaces, the liquid is pulled up along the solid, while for others, the liquid surface is convex or depressed near the solid surface. This phenomenon can be explained using the concept of cohesive and adhesive forces.
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
22.5K
Open Angle Glaucoma: Treatment
1.0K
In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
Drugs such as carbonic anhydrase inhibitors, α2- and...
1.0K
Angle of Twist: Problem Solving
807
An electric motor applies a torque of 700 N·m to an aluminum shaft, triggering a stable rotation. Two pulleys, B and C, are subjected to torques of 300 N·m and 400 N·m, respectively. The modulus of rigidity is provided as 25 GPa. With the knowledge of the length and diameter of each segment, the twist angle between the two pulleys can be computed. First, a section cut is made between pulleys B and C, and the cut cross-section is analyzed using a free-body diagram. Given that the torque...
807
Design Example: Traverse Angle Computations
342
Traverse angle computations are a critical component of surveying, used to compute the internal angles within a closed traverse. A traverse consists of a series of connected lines forming a closed loop, often used for land boundary delineation or mapping. Calculating the internal angles ensures accuracy in the traverse geometry and is essential for checking survey data integrity.The process begins with known azimuths and bearings of the traverse sides. Internal angles at each vertex are...
342
Angle Closure Glaucoma: Treatment
1.3K
Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
1.3K
Angle of Twist - Elastic Range
823
Consider a cylindrical shaft with a length denoted by L and a consistent cross-sectional radius referred to as r. This shaft undergoes a torque at the free end. The highest shearing strain within the shaft is directly proportional to the twist angle and the radial distance from the shaft axis. When the shaft behaves elastically, this shearing strain can be articulated using variables such as the applied torque, radial distance, the polar moment of inertia, and the modulus of rigidity. By...
823