在脑血管造影中,通过左半径方法进行内动脉导管治疗的反射线技术
Sheth Rishabh Hitendra1, Vikas Bhatia1, Ajay Kumar1
1Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research (PGIMER), Chandigarh, India.
概括
反射线技术在左侧透射血管造影期间有助于内动脉 (ICA) 导管. 这种方法对于导航复杂的大动脉形解剖学至关重要,提高了诊断脑血管造影的成功率.
科学领域:
- 血管外科 血管外科
- 干预性神经辐射学
- 诊断成像 诊断成像 诊断成像
背景情况:
- 左侧透射方法 (LTRA) 越来越多地用于诊断大脑血管造影.
- 通过LTRA实现双边内动脉 (ICA) 接入存在挑战.
- 了解影响ICA通道的因素对于程序成功至关重要.
研究的目的:
- 通过使用左侧透射方法,评估导致难以进入内动脉 (ICA) 的因素.
- 确定影响成功双边ICA导管治疗的解剖学和技术因素.
主要方法:
- 一项前性单中心分析研究,涉及32名接受诊断性脑血管造影的患者.
- 在所有情况下,都使用了左侧超辐射接入.
- 评估影响双边ICA导管治疗的因素,包括大动脉门解剖学和导线技术.
主要成果:
- 在100%的患者 (n=31) 中,成功的诊断血管造影.
- 右 ICA 导管成功率为 80.6% (25/31),左 ICA 的成功率为 77.4% (24/31).
- 反射线技术经常需要用于左侧ICA管道 (70.8%),而对右侧ICA管道 (36%) 则更少. 解剖学变异,如III型或牛大动脉门,与管难度和时间相关.
结论:
- 反射线技术是一种有效的方法,可以通过左侧辐射方法促进ICA导管注射.
- 特定的大动脉形态需要定制的技术来成功地进行LTRA脑血管造影.
相关概念视频
Total Internal Reflection Fluorescence Microscopy
13.5K
Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
13.5K
Internal Energy
36.8K
The total of all possible kinds of energy present in a substance is called the internal energy (U), sometimes symbolized as E. Suppose a system with initial internal energy, Uinitial, undergoes a change in energy (transfer of work or heat), and the final internal energy of the system is Ufinal. Change in internal energy equals the difference between Ufinal and Uinitial.
36.8K
Radial System Protection
447
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
447
Internal Receptors
74.7K
Many cellular signals are hydrophilic and therefore cannot pass through the plasma membrane. However, small or hydrophobic signaling molecules can cross the hydrophobic core of the plasma membrane and bind to internal, or intracellular, receptors that reside within the cell. Many mammalian steroid hormones use this mechanism of cell signaling, as does nitric oxide (NO) gas.
74.7K
Reflection of Waves
4.7K
When a wave travels from one medium to another, it gets reflected at the boundary of the second medium. A common example of this is when a person yells at a distance from a cliff and hears the echo of their voice. The sound waves (longitudinal waves) traveling in the air are reflected from the bounding cliff. Similarly, flipping one end of a string whose other end is tied to a wall causes a pulse (transverse wave) to travel through the string, which gets reflected upon reaching the wall. In...
4.7K
Assessment of radial pulse
1.5K
Assessment of Radial Pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
1.5K


