以排放趋势为约束的质量评估模型用于车辆NO排放的遥感数据
Junchao Zhao1, Li Peng2, Guanlin Zhu2
1State Key Laboratory of Regional Environment and Sustainability, School of Environment, Tsinghua University, Beijing 100084, China; Key Laboratory of Vehicle Emission Control and Simulation of Ministry of Ecology and Environment, Vehicle Emission Control Center, Chinese Research Academy of Environmental Sciences, Beijing 100012, China.
Journal of hazardous materials
|February 12, 2026
概括
本研究引入了一种机器学习框架 (RDEV),以提高车辆排放的遥感 (RS) 数据质量. 通过分析NO排放模式,RDEV提高了RS记录的可靠性,确保更准确的排放监测.
科学领域:
- 环境科学 环境科学
- 数据科学数据科学数据科学
- 汽车工程 汽车工程
背景情况:
- 遥感 (RS) 提供了一种用于监测在使用中的车辆排放的方法.
- 然而,RS的数据质量可能不一致,限制了其广泛应用.
- 高质量的RS (HQRS) 数据对于可靠的排放评估至关重要.
研究的目的:
- 开发一个机器学习框架 (RDEV),以提高车辆排放的RS数据的可用性和可靠性.
- 利用特有的NO排放模式来评估RS记录的可信度.
- 增强历史RS数据集的价值,用于排放研究.
主要方法:
- 通过受控活动获得高质量的RS (HQRS) 数据.
- 开发了RDEV机器学习框架,以使用NO排放模式根据年龄对车辆进行分类.
- 在HQRS测试子集上验证了RDEV模型的准确性.
主要成果:
- 在使用HQRS数据对已知年龄的车辆进行分类时,RDEV模型实现了86.95%的准确性.
- 当应用到常规监测数据时,RDEV减少了测量变化.
- RDEV将汽油汽车排放趋势与现有文献更紧密地协调一致.
结论:
- 通过学习已建立的排放模式,RDEV框架有效地选了庞大的RS数据集.
- 这种机器学习应用程序提高了数据质量,并增强了车辆排放监测历史RS数据的实用性.
- 在大规模遥感研究中,RDEV为选择高可信度数据提供了有价值的工具.
相关概念视频
Emission Spectra
76.6K
When solids, liquids, or condensed gases are heated sufficiently, they radiate some of the excess energy as light. Photons produced in this manner have a range of energies, and thereby produce a continuous spectrum in which an unbroken series of wavelengths is present.
76.6K
Positron Emission Tomography
7.7K
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
7.7K
Atomic Emission Spectroscopy: Lab
655
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
655
Molecular Spectroscopy: Absorption and Emission
4.7K
Molecules possess discrete energy levels called quantum states. Unlike atoms, which have simpler energy levels, molecules possess additional rotational and vibrational energy levels. Each energy level is separated by an energy gap, with the gaps between adjacent electronic, vibrational, and rotational levels varying significantly. The three types of energy levels in a diatomic molecule are shown in Figure 1.
4.7K
Atomic Emission Spectroscopy: Overview
3.8K
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
3.8K
Atomic Emission Spectroscopy: Instrumentation
1.3K
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
1.3K


