相关实验视频
Updated: Feb 15, 2026

12:11
Using Optical Tweezers for the Generation of Hybrid Spheroids
Published on: May 30, 2025
1.0K
微塑料的流塑测量使用光线子
Jee Won Lee1, Subeen Park1,2, Jin Il Jang1
1Department of Chemistry, Kookmin University, Seoul 02707, Republic of Korea.
ACS sensors
|February 13, 2026
概括
本研究介绍了一种用于分析水中的微塑料 (MP) 的新系统. 该方法允许实时,同时对MPs进行500nm的形态和化学表征.
科学领域:
- 环境科学 环境科学
- 分析化学 分析化学
- 材料科学 材料科学 材料科学
背景情况:
- 微塑料 (MP) 对生态系统和人类健康构成风险,在水生环境中存在显著存在.
- MP的毒性受化学成分和物理特征的影响.
- 目前的准备方法可能会改变MPs并干扰分析.
研究的目的:
- 开发用于微塑料表征的先进分析方法.
- 为了实现MPs的同时形态和化学分析.
- 为了促进水生系统中MP的实时监控.
主要方法:
- 开发了一种使用拉曼线监测和捕获的新系统.
- 一个用于光学固定的协议使拉曼信号能够从500纳米小的粒子中获取信号.
- 在流通道中同时进行了形态和化学分析.
主要成果:
- 该系统实现了MPs的同时形态和化学分析.
- 该协议成功地从亚微米粒子中获取了拉曼信号.
- 开发的方法为MP分析提供了一个强大的工具.
结论:
- 这种新系统提供了一种实时微塑料监测的强大方法.
- 这种技术克服了传统制备方法的局限性.
- 它有助于了解水生环境中微塑料相关的风险.
相关概念视频
Gene Flow
38.1K
Gene flow is the transfer of genes among populations, resulting from either the dispersal of gametes or from the migration of individuals.
38.1K
Properties of Enantiomers and Optical Activity
21.9K
It is essential to understand the difference between chiral and achiral interactions and the implications thereof in optical activity and their applications. Just as our feet, which are chiral, interact uniquely with chiral objects, such as a pair of shoes, but identically with achiral socks, enantiomers of a molecule exhibit different properties only when they interact with other chiral media. An example of a significant implication from this facet is the phenomenon known as optical activity,...
21.9K
Flow Cytometry
16.5K
The development of flow cytometry techniques began in 1934 with initial attempts by Andrew Moldavan, a bacteriologist who counted the cells in a flowing capillary system. Moldavan pumped cells through a capillary tube focused under a microscope for visualization. The invention of photometry allowed the measurement of differentially-stained cells, and Louis Kamentsky developed the first multiparameter flow cytometer in 1965 to identify and count the cancer cells in cervical tissue specimens.
In...
In...
16.5K
Flow Sheet
2.9K
Flowsheets are valuable tools in nursing documentation. They enable healthcare professionals to efficiently record and monitor various patient assessments and measurements in a consolidated format.
Here's a closer look at the examples of flowsheets commonly used by nurses:
Graphic Sheet Documentation:
Here's a closer look at the examples of flowsheets commonly used by nurses:
Graphic Sheet Documentation:
2.9K
Flow Table Test
772
The flow table test is an established method used to assess the workability of concrete, particularly useful for evaluating highly flowable concrete mixes. This test employs an apparatus that consists of a wooden board topped with a steel plate, collectively weighing 35 pounds. The board is connected to a base via a hinge and measures 27.6 inches on each side.
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
772
Irrotational Flow
1.0K
Irrotational flow is characterized by fluid motion where particles do not rotate around their axes, resulting in zero vorticity. For a flow to be irrotational, the curl of the velocity field must be zero. This imposes specific conditions on velocity gradients. For instance, to maintain zero rotation about the z-axis, the gradient condition:
1.0K