临床效用和TMS-EEG的前景:国际专家组的最新审查
Ulf Ziemann1, Yang Bai2, Fiona M Baumer3
1Department of Neurology & Stroke, University of Tübingen, Tübingen, Germany; Hertie Institute for Clinical Brain Research, University of Tübingen, Tübingen, Germany.
概括
结合的跨磁刺激 (TMS) 和脑电图 (EEG) 直接探测大脑功能. 本综述综合了TMS-EEG方法,人工物控制和神经和精神疾病的临床应用方面的进展.
科学领域:
- 神经科学是一个神经科学.
- 临床神经生理学 临床神经生理学
背景情况:
- 跨磁刺激 (TMS) 和电脑电图 (EEG) 是一种非侵入性脑部技术.
- 结合的TMS-EEG允许直接干扰大脑和同时记录反应,提供超越观察方法的因果洞察.
- 最近的进展包括与TMS兼容的EEG放大器,使联合技术成为可能.
研究的目的:
- 为结合TMS-EEG技术提供最新的共识审查.
- 综合了解和管理TMS-EEG信号工件的最新进展.
- 审查对TMS-EEG反应机制及其临床实用性的新见解.
主要方法:
- 关于TMS-EEG的当前文献的审查和综合.
- 专注于文物识别,避免和控制策略.
- 分析生理机制和TMS-EEG的诊断/预后应用.
主要成果:
- 在理解和减轻TMS-EEG信号中的人工物方面取得了实质性的进展.
- 新的见解揭示了TMS-EEG反应的生理基础.
- 人们越来越认识到TMS-EEG在各种疾病中的诊断和预后价值.
结论:
- 在临床神经生理学和神经科学中,TMS-EEG是一个快速发展的领域.
- 该技术为研究大脑动态和因果关系提供了无与伦比的机会.
- 本综述为临床实施提供了全面的综合和实际指导.
相关概念视频
Review and Preview
8.4K
In statistics, several tools are used to interpret the data. Measures of central tendency represent the characteristics of the data, such as mean, median, and mode. Additionally, measures of variance like standard deviation and range are used to find the spread of data from the mean. Relative standing measures the distance between data locations. Commonly used measures of relative standings are percentile, z score, and quartiles.
Percentiles are a type of fractile that partition data into...
Percentiles are a type of fractile that partition data into...
8.4K
Review and Preview
11.6K
Data are individual items of information obtained from a population or sample. Data may be classified as qualitative (categorical), quantitative continuous, or quantitative discrete. Because it is not practical to measure the entire population in a study, researchers use samples to represent the population. A random sample is a representative group from the population chosen by using a method that gives each individual in the population an equal chance of being included in the sample. Random...
11.6K
Internal Energy
36.9K
The total of all possible kinds of energy present in a substance is called the internal energy (U), sometimes symbolized as E. Suppose a system with initial internal energy, Uinitial, undergoes a change in energy (transfer of work or heat), and the final internal energy of the system is Ufinal. Change in internal energy equals the difference between Ufinal and Uinitial.
36.9K
Internal Energy
7.2K
The internal energy of a thermodynamic system is the sum of the kinetic and potential energies of all the molecules or entities in the system. The kinetic energy of an individual molecule includes contributions due to its rotation and vibration, as well as its translational energy. The potential energy is associated only with the interactions between one molecule and the other molecules of the system. Neither the system's location nor its motion is of any consequence as far as the internal...
7.2K
Internal Receptors
74.8K
Many cellular signals are hydrophilic and therefore cannot pass through the plasma membrane. However, small or hydrophobic signaling molecules can cross the hydrophobic core of the plasma membrane and bind to internal, or intracellular, receptors that reside within the cell. Many mammalian steroid hormones use this mechanism of cell signaling, as does nitric oxide (NO) gas.
74.8K
International System of Units
5.2K
The International System of Units, known as the SI system, is a universally accepted measurement system recognized and used worldwide. The SI system is based on a set of three base units considered absolute, and their values do not change with location. These base units are meters, kilograms, and seconds.
Prefixes are used to define both larger and smaller quantities in the SI system. For example, milli, micro, and nano define smaller quantities, while kilo, mega, and giga are used to define...
Prefixes are used to define both larger and smaller quantities in the SI system. For example, milli, micro, and nano define smaller quantities, while kilo, mega, and giga are used to define...
5.2K