关于GRIFFIN光谱仪中真实巧合总和的可测性
1Department of Physics, University of Guelph, Guelph, N1G 2W1, ON, Canada.
概括
核衰变测量中的真实巧合总结会产生虚假的峰值. 这项研究概括了一个校正形式主义,表明180度巧合方法对于大多数马射线光谱实验来说是足够的.
科学领域:
- 核物理 核物理 核物理
- 频谱学是一种光谱学.
背景情况:
- 马射线测量对于核结构研究至关重要.
- 真正的巧合总和导致由于总和的马射线能量导致不准确的能量光谱.
- 准确的对总和效应的纠正对于可靠的核衰变事件确定至关重要.
研究的目的:
- 为了概括Semkow等人. (1990) 将校正形式主义总结为矩阵形式主义.
- 为了提高准确性,将这种形式主义扩展为多重扩展.
- 开发和验证用于纠正马射线光谱中的巧合总和的方法.
主要方法:
- 将Semkow形式主义概括为Semkow矩阵形式主义.
- 对形式主义的多样性扩展的发展.
- 对180度巧合事件的概率计算.
- 对封闭的马射线进行分区矩阵形式主义的扩展.
主要成果:
- 完全和180度校正之间的偏差被分析为多重性的函数.
- 计算了封闭马射线的总和纠正概率,并分析了偏差.
- 一个玩具模型显示出10-3%的偏差.
结论:
- 一般化的矩阵形式主义和多重度扩展提供了准确的巧合总和纠正.
- 180度巧合方法已被证明对于大多数马射线光谱应用来说是足够的.
- 该研究定义了与巧合总和分析中的可测性和统计界限相关的关键术语.
相关概念视频
Mass Analyzers: Overview
1.8K
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
1.8K
Tandem Mass Spectrometry
2.6K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
2.6K
Mass Analyzers: Common Types
1.6K
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
1.6K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
801
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
801
High-Resolution Mass Spectrometry (HRMS)
2.7K
The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
2.7K
Mass Spectrometers
9.2K
This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
9.2K