使用200kV传输电子显微镜实现高质量的断层数据采集,采用双电容透镜系统的双电容透镜系统.
Lihong Chen1, Zhuofan Fang2, Qi Wen3
1Department of Obstetrics and Gynecology, Center for Reproductive Medicine, State Key Laboratory of Female Fertility Promotion, Peking University Third Hospital; Medical and Health Analysis Center, Peking University Health Science Center.
Journal of visualized experiments : JoVE
|February 23, 2026
概括
本研究详细介绍了一种高分辨率冷电子断层扫描 (cryo-ET) 数据收集的成本效益高的方法,使用Glacios显微镜上的开源SerialEM软件. 这种方法提高了结构生物学研究的可访问性.
科学领域:
- 结构生物学 结构生物学
- 生物物理学的生物物理.
- 显微镜的使用方法
背景情况:
- 低温电子断层扫描 (cryo-ET) 提供了对细胞组件的近原生结构洞察力.
- 传统的冷ET方法通常依赖于昂贵的专有软件,限制了可访问性.
- 化ET中的高分辨率成像需要精确控制传输电子显微镜 (TEM) 条件.
研究的目的:
- 为冷电子断层扫描 (cryo-ET) 数据采集建立一个开源的,具有成本效益的工作流.
- 适应和校准SerialEM软件,以在Glacios 2冷TEM上收集高质量的断层扫描数据.
- 为了证明这个工作流的可行性,从样本准备到数据分析.
主要方法:
- 在Glacios 2冷TEM上安装和全面校准开源SerialEM软件.
- 开发用于冷电子断层扫描 (cryo-ET) 的自动化数据收集策略.
- 使用阿波费里丁作为工作流验证的模型样本,包括断层图像重建和亚断层图像分析.
主要成果:
- 在Glacios 2显微镜上成功实现了SerialEM用于自动化,高质量的冷电子断层扫描 (cryo-ET) 数据采集.
- 证明了完整的工作流程,产生高分辨率的断层图像并使分断层图像分析成为可能.
- 验证了开源方法的成本效益和可访问性.
结论:
- 开源软件SerialEM的集成为冷ET数据收集提供了一个可行的和经济的替代方案.
- 这种工作流显著降低了使用冷电子断层扫描 (cryo-ET) 进行高级结构研究的入门障碍.
- 这种方法使Glacios显微镜的实验室能够在没有专有软件的情况下进行高分辨率的冷ET.
相关概念视频
Electron Microscope Tomography and Single-particle Reconstruction
3.0K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
3.0K
Transmission Electron Microscopy
7.4K
In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400...
7.4K
Overview of Electron Microscopy
15.7K
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
15.7K