用于健康监测的可穿戴传感器
Caroline Abreu1, Carla Bédard2, Jean-Christophe Lourme2
1ITODYS, CNRS, Université Paris Cité, 75006 Paris, France.
Biosensors
|February 26, 2026
概括
可穿戴传感器为老龄化人口提供持续的健康监测,降低医疗保健成本. 这项技术能够早期发现健康问题,促进及时干预和独立生活.
科学领域:
- 生物医学工程 生物医学工程
- 医疗信息学 医疗信息学
- 传感器技术 传感器技术
背景情况:
- 全球人口增长和人口老龄化正在增加医疗保健支出.
- 医疗保健系统正在向持续的远程监控过渡,以管理成本和改善护理.
- 传感器,嵌入式系统和无线通信方面的技术进步使智能健康监测解决方案成为可能.
研究的目的:
- 审查最近在可穿戴,基于传感器的人类活动监控方面的进展.
- 要突出健康监测应用,生物标志物和传感器技术.
- 讨论可穿戴传感器研究和应用中的挑战和未来前景.
主要方法:
- 对人类活动监测可穿戴和可植入传感器的最新文献的审查.
- 分析医疗保健中既有和新兴的传感器技术.
- 讨论研究,开发和应用这些传感器的挑战.
主要成果:
- 可穿戴式传感器可以有效地监测生理指标和症状,以便早期检测事件.
- 有各种可穿戴和可植入的传感器可用于健康监测,并使用成熟的技术.
- 这些传感器的研究,开发和广泛应用仍然存在重大挑战.
结论:
- 可穿戴传感器对于持续的健康监测至关重要,能够及时提供帮助并减少住院患者.
- 需要进一步的研究和开发来克服挑战,并促进这些技术的采用.
- 广泛使用可穿戴传感器可以显著改善人类健康监测和管理.
相关概念视频
Holter Monitor: 24-Hour Monitoring
3.2K
Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
3.2K
Pulse rhythm
1.5K
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
1.5K
Equipments Used To Measure Blood Pressure
3.8K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
3.8K
Equipments Used to Measure Body Temperature
1.9K
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
1.9K
Guidelines For Measuring Vital Signs
3.0K
Following these guidelines can help nurses accurately measure vital signs, assess changes in patient conditions, and provide timely treatment when necessary. Adhering closely to the guidelines ensures the accuracy and reliability of the results.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
3.0K
Sites for measuring blood pressure
3.9K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
3.9K