临时水泥清洗方法对树脂-丁丁结合强度的影响,在用不同的粘合系统立即密封丁丁后
Zeynep Aydin1, Cemile Kedici Alp1, Osman F Aydin2
1Department of Restorative Dentistry, Faculty of Dentistry, Gazi University, Emek, Ankara 06490, Türkiye.
Journal of functional biomaterials
|February 26, 2026
概括
即时牙密封 (IDS) 提高了树脂-牙结合强度,但临时水泥污染显著降低了它. 目前的清洁方法无法完全恢复损坏的结合强度,强调污染预防.
科学领域:
- 牙科材料科学 牙科材料科学
- 粘合式牙科 粘合式牙科
- 恢复性牙科 恢复性牙科
背景情况:
- 即时牙密封 (IDS) 是一种提高树脂水泥与牙的结合强度的技术.
- 在间接修复过程中使用临时水泥,它们的污染可能会损害最终的结合.
- 了解IDS后临时水泥去除方法的有效性对于临床成功至关重要.
研究的目的:
- 评估不同临时化水泥去除技术对树脂水泥与牙的剪接强度 (SBS) 的影响.
- 通过两种不同的粘合系统,评估直接牙密封 (IDS) 后的清洁方法的有效性.
- 调查临时水泥污染和随后的清洁对树脂-丁丁粘合物的影响.
主要方法:
- 用于使用OptiBond FL或G2-Bond或没有IDS的168个人类牙进行IDS.
- 施加了临时水泥,然后用手动缩放器,Al2O3空气磨损或Katana清洁剂进行清洁.
- 切割键强度 (SBS) 在24小时的水储存后进行了测试.
- 扫描电子显微镜 (SEM) 评估了表面形态.
主要成果:
- 在未受污染的标本中,IDS显著增加了SBS;G2-Bond显示的值高于没有IDS.
- 暂时的水泥污染显著减少了SBS,无论清洗方法如何.
- 没有一项经过测试的清洁方案能够完全恢复因污染而受到损害的结合强度.
- 在SEM中,即使在宏观清洁的样本中,也发现了清洁后的剩余水泥和表面变化.
结论:
- 当避免污染时,立即的牙密封增强了树脂-牙结合.
- 目前的机械和化学清洗方法不足以完全恢复由于临时水泥污染而失去的结合强度.
- 在间接修复过程中,防止污染和维护IDS层的完整性至关重要.
更多相关视频
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
908
05:30Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
1.1K
相关概念视频
Bonding and Strength of Aggregate
536
The bond between aggregate particles and the cement matrix is significantly influenced by the shape and surface texture of the aggregates. High-strength concretes benefit from a rougher texture, which leads to stronger bonding due to greater adhesion. Angular aggregates with larger surface areas also enhance this bond. The bonding quality, however, is complex to assess as no universally accepted test exists. Good bonding is indicated when a crushed concrete specimen shows some aggregate...
536
Testing Water Quality
421
When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
421
Strength of Cement
654
Strength tests for cement are not performed directly on neat cement paste due to difficulty in obtaining consistent, reliable specimens. Instead, cement is typically tested in the form of cement-sand mortar.
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
654
Curing of Concrete
413
The hydration of cement takes place within the water-filled capillary pores. However, environmental elements can disrupt this process by evaporating water from the concrete surfaces. Sealed concrete with a water-cement ratio below 0.5 experiences self-desiccation, leading to water loss. The water loss in concrete is mitigated by curing. This technique involves keeping the concrete saturated to maintain the necessary temperature and moisture conditions, to optimally fill the spaces in the cement...
413
Strength and Heat of Hydration
775
The hydration of cement is an exothermic reaction in which heat is generated as cement hydrates. This heat of hydration is critical to cement's strength development. The rate at which this heat is generated affects the temperature rise, with a majority of the heat being released early in the hydration process, half within the first three days, and about 75% within the first week.
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
775
Types of Cement I
431
Portland cement comes in several types, each with distinct properties and applications based on their chemical composition and hydration characteristics:
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...
431