在新的电力系统中对新出现的DDoS威胁的调查
Fan Luo1, Siqi Fan1, Guolin Shao2
1College of Information Engineering, Nanchang University, Nanchang 330031, China.
Sensors (Basel, Switzerland)
|February 27, 2026
概括
分布式拒绝服务 (DDoS) 攻击正在演变为多阶段的操作. 本研究提出了三阶段的DDoS攻击链,以更好地理解和防御这些复杂的网络威胁.
科学领域:
- 网络安全 网络安全
- 网络安全 网络安全
- 应用计算机科学 应用计算机科学
背景情况:
- 分布式拒绝服务 (DDoS) 攻击是一种持久的网络威胁,经常用于地缘政治冲突.
- 传统的DDoS分析通常将攻击视为单步事件,忽视了不断发展的多阶段战术.
- 无处不在的智能和连接的兴起使复杂的,多阶段的DDoS活动成为可能.
研究的目的:
- 为当代DDoS行动提出一种新的三阶段攻击链模型.
- 分析2019-2024年DDoS攻击中不断变化的战术,技术和程序 (TTP).
- 确定加强DDoS防御机制的研究方向.
主要方法:
- 对2019年至2024年的DDoS事件进行分析.
- 开发一个三阶段的DDoS攻击链:准备,开发和执行.
- 对当代DDoS模式及其对新技术的依赖性进行审查和分类.
- 对现有的DDoS防御策略的调查.
主要成果:
- 越来越多的DDoS攻击是多阶段的,利用新的硬件,网络架构和协议.
- 一个三个阶段的攻击链模型 (准备,开发,执行) 有效地捕捉了现代的DDoS战术.
- 目前的防御需要适应,以应对先进的DDoS活动的复杂性.
结论:
- 了解DDoS作为一个多阶段的攻击链对于有效的防御至关重要.
- 未来的研究应该专注于跨层遥测,强大的机器学习,自动化缓解和合作取消.
- 调整防御以适应不断发展的DDoS战术对于应对网络威胁至关重要.
相关概念视频
Power System Distribution
1.1K
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
1.1K
Distribution Reliability and Automation
542
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
542
Fast Decoupled and DC Powerflow
790
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
790
Zones of Protection
862
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
862
Power System Three-Phase Short Circuits
594
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
594
Pilot and Numeric Relaying
503
Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
503