寻找新的复杂序列来实现小型空载雷达的航空集团交互系统
Vadim A Nenashev1, Renata I Chembarisova1, Aleksandr R Bestugin1
1Saint-Petersburg State University of Aerospace Instrumentation, 67, Bolshaya Morskaia Str., 190000 St. Petersburg, Russia.
Sensors (Basel, Switzerland)
|February 27, 2026
概括
研究人员开发了新的复杂的M序列,用于组交互的紧型机载雷达系统 (CORS). 这些序列可以在共享道中进行独特的信号识别,改善合作地表映射和合作传感能力.
科学领域:
- 雷达系统工程 雷达系统工程
- 信号处理 信号处理
- 合作式传感传感器
背景情况:
- 集团交互的紧型机载雷达系统 (CORS) 越来越多地用于表面绘图.
- 合作运行需要每个雷达的独特,可区分的探测信号,以避免干扰.
研究的目的:
- 在CORS中寻找新的复杂M序列用于相调节.
- 为了更好地识别信号,在自相关函数中实现较低的侧叶水平.
主要方法:
- 使用不对称的复杂数集开发了新的复杂M序列.
- 采用数值方法和计算机模拟来确定最佳的复杂值.
- 研究的相关性质和相调节信号.
主要成果:
- 确定了新的复杂M序列,其侧叶水平明显低于传统M序列.
- 证明了这些序列在共享雷达通道内的信号区分方面的有效性.
- 验证了加强合作地表探测的潜力.
结论:
- 开发的复杂M序列为基于组的技术视觉系统提供了更好的性能.
- 这些序列可以在相互作用的CORS之间进行强大的合作表面探测.
- 在合作系统中开辟了先进雷达信号设计的新途径.
相关概念视频
Multi-input and Multi-variable systems
441
Cruise control systems in cars are designed as multi-input systems to maintain a driver's desired speed while compensating for external disturbances such as changes in terrain. The block diagram for a cruise control system typically includes two main inputs: the desired speed set by the driver and any external disturbances, such as the incline of the road. By adjusting the engine throttle, the system maintains the vehicle's speed as close to the desired value as possible.
In the absence of...
In the absence of...
441
Signal Sequences and Sorting Receptors
15.6K
Signal sequences are short amino acid sequences that guide newly synthesized proteins to their proper location within the cell. Classical signal sequences are fifteen to sixty amino acids long and present at the N-terminus of a polypeptide chain. Each signal sequence has a conserved segment of basic residues towards their N terminus, a hydrophobic core, and a C-terminus rich in polar residues. The C-terminus also contains a signal cleavage site and features a -3 -1 sequence motif. The -3-1...
15.6K
Sequence Networks of Rotating Machines
510
A Y-connected synchronous generator, grounded through a neutral impedance, is designed to produce balanced internal phase voltages with only positive-sequence components. The generator's sequence networks include a source voltage that is exclusively in the positive-sequence network. The sequence components of line-to-ground voltages at the generator terminals illustrate this configuration.
Zero-sequence current induces a voltage drop across the generator's neutral impedance and other...
Zero-sequence current induces a voltage drop across the generator's neutral impedance and other...
510
Control Systems: Applications
1.3K
Electrical engineering plays a pivotal role in our daily lives, with control systems at the heart of many applications, from home appliances to sophisticated space shuttles. Control systems manage and regulate the behavior of devices and processes, ensuring they function safely, correctly, and efficiently.
In modern vehicles, control systems manage various functions to enhance performance and safety. The steering wheel and accelerator are primary inputs in a car's control system. The...
In modern vehicles, control systems manage various functions to enhance performance and safety. The steering wheel and accelerator are primary inputs in a car's control system. The...
1.3K
One-Degree-of-Freedom System
879
In mechanical engineering, one-degree-of-freedom systems form the basis of a wide range of electrical and mechanical components. Using these models, engineers can predict the behavior of various parts in a larger system, which gives them insight into how different forces interact with each other.
A one-degree-of-freedom system is defined by an independent variable that determines its state and behavior. One example of a one-degree-of-freedom system is a simple harmonic oscillator, such as a...
A one-degree-of-freedom system is defined by an independent variable that determines its state and behavior. One example of a one-degree-of-freedom system is a simple harmonic oscillator, such as a...
879
Pilot and Numeric Relaying
503
Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
503