5G网络边缘智能用于海上风电智能运行和维护
Yuqing Gao1, Lingang Yang1, Xialiang Zhu1
1PowerChina Huadong Engineering Corporation Limited, Hangzhou 311100, China.
Sensors (Basel, Switzerland)
|February 27, 2026
概括
智能操作和维护 (O&M) 对海上风电场至关重要. 本研究探讨了5G边缘智能架构,以克服通信挑战,并在恶劣的海洋环境中提高O&M效率.
科学领域:
- 可再生能源系统可再生能源系统
- 电信工程 电信工程 电信工程
- 人工智能的人工智能
背景情况:
- 海上风力发电扩展到更深的水域带来了重大运营和维护 (O&M) 挑战.
- 由于带宽,延迟和成本限制,现有的通信基础设施 (4G,卫星) 对于智能O&M是不够的.
- 对于在偏远的海上环境中进行先进的监控和控制,需要强大的高速通信至关重要.
研究的目的:
- 为远程海上智能风电场解决智能服务通信需求.
- 调查并提出针对海上风电场O&M量身定制的有效5G部署方案.
- 为增强海上风电场运营开发一个集成的5G边缘情报架构.
主要方法:
- 分析各种5G部署策略,包括混合网络,频率选择和轮内覆盖.
- 实践用例和核心边缘情报应用程序的研究,如设备监控,检查和故障诊断.
- 构建一个全面的"终端边缘云网络" 5G边缘智能集成架构.
主要成果:
- 对5G在海上风电O&M中的关键技术影响和实际实施案例的评估.
- 展示边缘智能应用程序,增强设备监控,预测性维护和数字双胞胎集成.
- 确定统一的"终端边缘云网络"架构的好处,以实现无的数据流和处理.
结论:
- 5G边缘智能提供了一种可行的解决方案,以克服海上风电场O&M的通信障碍.
- 拟议的集成架构有效支持先进的智能服务,提高运营效率和可靠性.
- 未来的研究应该专注于在边缘部署轻量级的大型语言模型,以进一步推进O&M.
相关概念视频
Wind Turbine Machine Models
635
In the growing field of wind energy, incorporating wind turbine models into transient stability analysis is essential. Induction and synchronous machines are the primary models used, with induction machines being prevalent due to their simplicity and reliability.
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
635
Energy Line and Hydraulic Gradient Line
2.6K
Based on Bernoulli's equation, the energy line (EL) and hydraulic grade line (HGL) provide graphical representations of energy distribution in a fluid flow system. For steady, incompressible, inviscid flows, Bernoulli's equation is expressed as:
2.6K
Power System Distribution
1.1K
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
1.1K
Turbine-Governor Control
1.0K
Turbine-governor control is crucial for maintaining power system stability by balancing turbine mechanical power output with electrical load demand. This mechanism ensures that generator frequency and rotor speed are within acceptable limits during load variations. Turbine-generator units store kinetic energy due to their rotating masses; this energy is released to meet the load requirement when the load increases. The electrical torque of turbines rises to meet the demand, whereas the...
1.0K
Maximum Power Transfer
1.0K
Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
By substituting the entire circuit with...
1.0K
Electrical Power
3.8K
Electric power is the product of current and voltage, represented in units of joules per second, or watts. For example, cars often have one or more auxiliary power outlets with which you can charge a cell phone or other electronic devices. These outlets may be rated at 20 amps and 12 volts, so that the circuit can deliver a maximum power of 240 watts. Consider a 25 Watt bulb and a 60 Watt bulb. The conversion of electrical energy produces heat and light, while the kinetic energy lost by the...
3.8K