为了协调单粒子感应合等离子体质谱的原始数据处理
Isabel Abad-Alvaro1, Eduardo Bolea1, Francisco Laborda1
1Group of Analytical Spectroscopy and Sensors (GEAS), Institute of Environmental Sciences (IUCA), University of Zaragoza, Pedro Cerbuna 12, 50009, Zaragoza, Spain.
Talanta
|February 28, 2026
概括
这项研究验证了单粒子感应合等离子体质谱仪 (SP-ICP-MS) 的数据处理,通过协调四极仪器的临界值计算来确保可靠的粒子计数和强度测量.
科学领域:
- 分析化学 分析化学
- 材料科学 材料科学 材料科学
背景情况:
- 对于SP-ICP-MS的高级数据处理工具缺乏验证,这阻碍了用户对结果的信任.
- 为了可靠的粒子分析,需要对数据处理标准进行协调.
研究的目的:
- 评估目前的SP-ICP-MS数据处理方法用于四极管.
- 促进基线和粒子歧视,事件计数和强度决定的临界值计算的协调.
主要方法:
- 对SP-ICP-MS.数据处理标准和表达式的深入评估.
- 基于基线强度的基线/粒子歧视的Poisson和Gaussian方法的评估.
- 使用开源工具SPCal与纳米和微粒子悬浮的验证.
主要成果:
- 基线强度对于选择适当的歧视方法至关重要 (Poisson与Gaussian).
- 覆盖率为5的覆盖因子将在各种条件中最大限度地减少假阳性 (<10).
- 覆盖率较低的因素会增加假阳性,特别是对于纳米粒子和短暂停留时间.
结论:
- 具有适当的临界值的SPCal提供可靠的粒子计数和强度数据.
- 提出的临界值计算方法验证了专有软件,突出了特定条件中的差异.
更多相关视频
相关概念视频
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
2.3K
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
2.3K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
1.5K
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
1.5K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
2.0K
Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
2.0K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
862
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
862
Tandem Mass Spectrometry
2.7K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
2.7K
Mass Analyzers: Overview
1.9K
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
1.9K