综合超临界流体提取和在线ICP-MS的的纳米克测定 (IV) 使用calixarene酸
Devarshi Thaker1, Bignesh Thakur2, Nirav Pandya3
1Faculty of Science, Nirma University, Ahmedabad-382481, Gujarat, India.
Analytical methods : advancing methods and applications
|March 2, 2026
概括
一种新的方法有效地提取和检测微量 (IV) 使用超临界流体提取 (SFE) 与ICP-MS相结合. 这种环保技术为复杂的样本分析提供了高灵敏度和精度.
科学领域:
- 分析化学 分析化学
- 环境科学 环境科学
背景情况:
- 精确确定微量对于各种工业和环境应用至关重要.
- 现有的分析方法可能耗时,可能涉及危险化学品.
研究的目的:
- 开发一种选择性,高效和环保的方法来确定微量.
- 为了整合超临界流体提取 (SFE) 与卡利沙林酸 (CC4AHA) 和ICP-MS进行在线分析.
主要方法:
- 系统优化SFE条件:温度,压力,提取时间,酸度和有机修饰剂.
- 在线合SFE与感应合等离子体质谱 (ICP-MS) 进行实时检测.
- 使用二甲修饰的超临界CO2和8.0M HCl用于定量Ti(IV) 恢复.
主要成果:
- 在最佳条件下 (50°C,17MPa,5-6分钟) 实现了Ti(IV的定量回收 (>99.9%).
- 在0.23-2.18 ng mL-1度范围内表现出极好的线性 (R2 > 0.999).
- 报告了低检测极限 (0.78 ng mL-1) 和定量 (2.34 ng mL-1),具有高精度 (<5% RSD) 和准确性 (96-104%的恢复).
结论:
- 开发的SFE-ICP-MS方法对于超微量的确定是快速,灵敏和准确的.
- 在认证的参考材料和复杂的现实世界样本中成功应用了分析的方法.
- 呈现了一种更绿色的分析替代方案,用于不同矩阵中的分析.
相关概念视频
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
2.3K
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
2.3K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
1.5K
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
1.5K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
2.0K
Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
2.0K