对于具有零错误跟踪的不确定的非线性系统,固定时间命令过的自适应后退控制
IEEE transactions on cybernetics
|March 3, 2026
概括
本研究引入了非线性系统的自适应固定时间控制,确保追踪错误在固定时间内趋于零. 这种新的方法提高了不确定性系统的稳定性和计算效率.
科学领域:
- 控制工程 控制工程 控制工程
- 非线性系统理论 非线性系统理论
- 适应性控制系统 适应性控制系统
背景情况:
- 现有的自适应固定时间控制方法往往侧重于局限错误轨迹跟踪.
- 具有时间变化的参数和干扰的非线性系统带来了重大的控制挑战.
研究的目的:
- 开发一种新的基于命令波器的适应性固定时间跟踪控制方案.
- 为非线性系统解决现有的固定时间控制策略的局限性.
- 为了减少计算复杂性,同时确保强大的跟踪性能.
主要方法:
- 基于指数式衰变函数提出了一个新的固定时间稳定定理.
- 在控制方案构建中采用命令过后退技术.
- 整合一个零碎的功能,以保证虚拟控制规律的二次导出性.
主要成果:
- 拟议的控制方案确保追踪误差在固定的时间内趋于零.
- 该战略有效地应对时间变化的不确定参数和干扰.
- 与现有方法相比,计算复杂性降低了.
- 虚拟控制规律的二次导出性得到保证,确保命令波器的有效性.
结论:
- 新的自适应固定时间控制策略为非线性系统提供了更好的性能.
- 该方法在存在不确定性和干扰的情况下提供了强大的跟踪控制.
- 模拟结果验证了拟议的控制方案的有效性和实际适用性.
更多相关视频
08:18WheelCon: A Wheel Control-Based Gaming Platform for Studying Human Sensorimotor Control
Published on: August 15, 2020
4.3K
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
1.7K
相关概念视频
Feedback control systems
800
Feedback control systems are categorized in various ways based on their design, analysis, and signal types.
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
800
Controller Configurations
484
Controller configurations are crucial in a car's cruise control system because they manage speed over time to maintain a consistent pace regardless of road conditions, thereby meeting design goals. In traditional control systems, fixed-configuration design involves predetermined controller placement. System performance modifications are known as compensation.
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
484
Time-Domain Interpretation of PD Control
500
Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Consider the example of control of motor torque. Initially, a positive...
500
PI Controller: Design
1.6K
Proportional Integral (PI) controllers are a fundamental component in modern control systems, widely used to enhance performance and mitigate steady-state errors. They are particularly effective in applications such as automatic brightness adjustment on smartphones, where they excel at mitigating steady-state errors for step-function inputs. Unlike PD controllers, which require time-varying errors to function optimally, PI controllers leverage their integral component to address residual...
1.6K
Time and frequency -Domain Interpretation of PI Control
503
Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
503
Time and frequency -Domain Interpretation of Phase-lag Control
472
Phase-lag controllers are widely used in control systems to improve stability and reduce steady-state errors. A dimmer switch controlling the brightness of a light bulb serves as a practical example of phase-lag control, gradually adjusting the bulb's brightness. Mathematically, phase-lag control or low-pass filtering is represented when the factor 'a' is less than 1.
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
472