在法医爆炸物调查中的活动级解读:研究从闪光粉中转移化物痕迹的研究
I M van Damme1, M E Corver2, C S Soemai2
1Van 't Hoff Institute for Molecular Sciences, Faculty of Science, University of Amsterdam, the Netherlands.
Forensic science international
|March 6, 2026
概括
酸盐是闪光粉的标记物,易于在手和物体之间转移. 棉花保留了最多的甲酸盐,随着每次接下来的接触,含量显著减少.
科学领域:
- 法医科学 法医科学 法医科学
- 分析化学 分析化学
背景情况:
- 闪光粉是一种甲和混合物,是荷兰普遍存在的爆炸物.
- 甲酸盐作为一个关键的分析标记,用于识别闪光粉处理.
研究的目的:
- 调查酸盐的转移,持久性,流行率和恢复 (TPPR).
- 为了使活动级别的评估能够超越简单的爆炸物处理的识别.
主要方法:
- 模仿了各种手对物体接触场景,产生了超过2000个传输时刻.
- 分析了酸盐在不同表面的转移和保留,包括棉花,皮肤和光滑材料.
主要成果:
- 在常见的交互过程中,甲酸盐很容易在手和物体之间转移.
- 棉花表现出最高的酸盐保留率,其次是皮肤,然后是光滑的表面.
- 每次接下来的接触都导致转移的甲酸盐大约在数量级下降.
结论:
- 实验数据支持在法医调查中对TPPR事件进行概率分配.
- 转移数据有助于计算活动级提案的证据强度.
- 需要对长期持久性和初始量进行进一步的研究,以进行可靠的活动级别评估.
更多相关视频
07:22Standardized Method for Measuring Collection Efficiency from Wipe-sampling of Trace Explosives
Published on: April 10, 2017
10.0K
06:52Laboratory Scale Slow Cook-Off Testing of Rocket Propellants: The Combustion Rate Analysis of a Slowly Heated Propellant CRASH-P Test
Published on: February 6, 2021
4.4K
相关概念视频
Flame Photometry: Lab
1.1K
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
1.1K
Atomic Absorption Spectroscopy: Lab
1.2K
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
1.2K
Volatilization
6.3K
Volatilization gravimetry is an analytical technique that measures the mass lost due to the volatilization of the substance. This technique is used to estimate the amount of volatile material in a sample. To perform this method, heat a known amount of the sample to a high temperature in a crucible or other suitable vessel. The volatile substance in the sample evaporates, and the vapor is completely expelled from the crucible either by heating the sample or bubbling a stream of inert gas through...
6.3K
Atomic Emission Spectroscopy: Interference
706
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
706
Atomic Emission Spectroscopy: Lab
744
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
744
Atomic Absorption Spectroscopy: Atomization Methods
1.7K
Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the...
1.7K