适应临床化学等离子体作为液体活检的来源
medRxiv : the preprint server for health sciences
|March 11, 2026
概括
常规临床化学测试中的残留血是无细胞DNA (cfDNA) 生物储存和测试的可行来源. 这种可访问的cfDNA资源为分子分析提供了高一致性,支持其在诊断中的使用.
科学领域:
- 分子诊断学 分子诊断
- 基因组学就是基因组学.
- 这是生物银行.
背景情况:
- 循环无细胞DNA (cfDNA) 对于分子测试至关重要,但通常需要专门收集或立即处理.
- 在临床化学中常见的氨酸分离器,是cfDNA分析中未充分利用的来源.
研究的目的:
- 评估使用氨酸分离器的残留血用于cfDNA生物库和测试的可行性.
- 评估从肝素分离器血中获得的cfDNA分析与标准方法 (EDTA,Streck管) 的一致性.
主要方法:
- 分析了来自健康志愿者的匹配血样本和病毒PCR阳性患者队列.
- 实验包括立即处理的比较和模拟的临床处理与延迟处理.
- 分析涉及全基因组和甲基化测序,以评估cfDNA完整性,甲基化模式,碎片组学和病毒检测.
主要成果:
- 在立即处理下,肝素分离器血对甲基化模式和碎片化特征与EDTA和Streck血具有很高的一致性.
- 肝素分离器中的cfDNA完整性在模拟临床处理期间冷藏时与EDTA管相比.
- 在临床队列中观察到病毒检测,复制数改变概况和甲基化模式的强烈一致性.
结论:
- 常规临床化学测试中的残留血,当及时处理和冷藏时,是cfDNA生物库的宝贵和尚未开发的资源.
- 这种方法提高了cfDNA测试和分子诊断的可访问性.
- 这些发现支持将肝素分离器血集成到cfDNA生物银行策略中.
相关概念视频
Gas Chromatography: Types of Detectors-II
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
High-Performance Liquid Chromatography: Types of Detectors
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
Atomic Absorption Spectroscopy: Interference
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Lab
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...