使用测量强度的液晶可变减速器对斯托克斯极度计进行校准
Luis Muñoz-Flores1, Neil C Bruce1
1Instituto de Ciencias Aplicadas y Tecnología, Universidad Nacional Autónoma de México, Circuito Exterior S/N, Ciudad Universitaria, 04510 Mexico City, Mexico.
The Review of scientific instruments
|March 11, 2026
概括
这项研究优化了使用液晶变量延迟器的斯托克斯极相仪配置. 与以前的技术相比,一种新的校准方法提高了准确性和稳定性.
科学领域:
- 光学工程是指光学工程.
- 计量学 计量学 计量学
- 仪器化 仪器化 仪器化
背景情况:
- 斯托克斯极度计对于光学特征表征至关重要.
- 液晶变量延迟器提供可调节的极化控制.
- 优化极相仪配置可以提高测量精度.
研究的目的:
- 分析和优化三个斯托克斯极相仪配置.
- 开发和验证这些极度计的新校准方法.
- 将新校准的性能与现有方法进行比较.
主要方法:
- 基于条件数 (κ=3) 的极相仪配置的优化.
- 开发一种新的校准技术,使用已知的样品和延迟器的强度变化.
- 与以前发表的非线性适配校准方法进行比较.
主要成果:
- 所有三个研究的配置都被优化为 κ=3.
- 新的校准方法在所有配置中产生了一致的结果.
- 拟议的校准表明总体误差略低于以前的方法.
- 新方法更简单,更稳定,更强大.
结论:
- 这种新的校准方法为斯托克斯极度计提供了卓越的性能.
- 优化的极相仪配置与新的校准相结合,提高了测量准确性和可靠性.
- 这种方法为光学计量学提供了实际的进步.
相关概念视频
Measuring Reaction Rates
32.6K
Polarimetry finds application in chemical kinetics to measure the concentration and reaction kinetics of optically active substances during a chemical reaction. Optically active substances have the capability of rotating the plane of polarization of linearly polarized light passing through them—a feature called optical rotation. Optical activity is attributed to the molecular structure of substances. Normal monochromatic light is unpolarized and possesses oscillations of the electrical...
32.6K
Stokes' Law
3.1K
Viscous forces, like friction, are intermolecular forces that resist the relative motion of molecules over each other. When a solid body moves through a liquid, viscous forces drag it in the opposite direction. The force's magnitude depends on the solid's shape and size, as well as its speed and the liquid's coefficient of viscosity, density and temperature.
The expression for the force on a solid spherical object in a fluid is called Stokes' law. Stokes' law is valid only...
The expression for the force on a solid spherical object in a fluid is called Stokes' law. Stokes' law is valid only...
3.1K
Instrument Calibration
957
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
957
Calibration Curves: Linear Least Squares
4.8K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
For data that follow a straight line, the standard method for fitting is the linear...
4.8K